Where circulation paths are interior, required accessible routes shall also be interior....
Search Results "Interior Door"
Commonly Searched Documents
-
11B-206.3 Location
-
11B-206.3 Location
Where circulation paths are interior, required accessible routes shall also be interior....
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
Thresholds: ADA Standard Section 404.3.3
Section 404.3.3 covers the current ADA Standards for thresholds at automatic and power-assisted doors and gates.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
Door and Gate Hardware [§404.2.7]
Door and Gate Hardware [§404.2.7] Door and gate hardware must: allow one-hand operation not require tight grasping, pinching, or twisting of the wrist operate...
-
304.4 Door Swing
304.4 Door Swing. Doors shall be permitted to swing into turning spaces....
-
Furniture in Space with Clutter
This (slide 6) is a blowup of a plan from, like, a 1940s or ‘50s German office building. This was the idea of an open office plan where you could be flexible and you could be within...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
Recessed Doors and Gates [§404.2.4.3]
Recessed Doors and Gates [§404.2.4.3] Thick walls, casework, shelving, columns and other elements can cause doors or gates to be recessed....
-
1010.1.4.1 Revolving doors
Revolving doors shall comply with the following: 7. Revolving doors shall not be part of an accessible route required by Section 1009 and Chapter 11A or 11B....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
206.3 Location
Where circulation paths are interior, required accessible routes shall also be interior....
-
404.2.1 Revolving Doors, Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
404.2.1 Revolving Doors, Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Maneuvering Clearance or Standby Power for Automatic Doors
Maneuvering Clearance or Standby Power for Automatic Doors. Section 4.13.6 of the 1991 Standards does not require maneuvering clearance at automatic doors....
-
Doors and hardware
• Minimum-weight doors with accessible hardware are easily opened by people who have arthritis or use a cane for extra balance....
-
Power Operation: ADA Standard Section 409.3.1
Section 409.3.1 covers the current ADA Standards for the power operation of private residence elevator doors.
-
4.10.8 Door Delay for Car Calls
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
4.10.8 DOOR DELAY FOR CAR CALLS
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
Doors and Gates Operated Only By Security Personnel [§404.1, Ex] Manual doors, doorways, and gates that are designed to be operated only by security personnel, such as guards in...
-
Door Hardware
A few commenters requested that lever hardware be required on doors throughout dwelling units, not only at the entry door to the dwelling unit. Response....