The cross slope of ramp surfaces shall be no greater than 1:50. Ramp surfaces shall comply with 4.5.
Search Results "Incremental Change"
Commonly Searched Documents
- 
    
  
  4.8.6 Cross Slope and Surfaces
  
- 
    
  
  4.8.6 CROSS SLOPE AND SURFACES
  The cross slope of ramp surfaces shall be no greater than 1:50. Ramp surfaces shall comply with 4.5. 
- 
    
  
  1016.5 Obstacles
  Obstacles on outdoor recreation access routes, passing spaces, and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest... 
- 
    
  
  1017.5 Tread Obstacles
  Tread obstacles on trails, passing spaces, and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. EXCEPTION: Where the surface... 
- 
    
  
  § 38.83(b)(8) Platform entrance ramp
  (8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and... 
- 
    
  
  § 38.159(b)(8) Platform entrance ramp
  (8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75... 
- 
    
  
  Floor or Ground Surfaces: ADA Standard Section 502.4
  Section 502.4 covers the current ADA Standards for the floor or ground surfaces of accessible parking spaces. 
- 
    
  
  Changes in Level within a Dwelling Unit
  For single-story dwelling units and multistory dwelling units, the Guidelines for Requirement 4 are as follows: (1) For single-story dwelling units, the design specifications for changes... 
- 
    
  
  305.2 Floor or Ground Surfaces
  Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.... 
- 
    
  
  305.2 Floor or Ground Surfaces
  Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.... 
- 
    
  
  11B-305.2 Floor or ground surfaces
  Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted... 
- 
    
  
  11B-305.2 Floor or ground surfaces
  Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.... 
- 
    
  
  305.2 Floor or Ground Surfaces
  Changes in level are not permitted. [ECTCR UFAS 4.2.4.3] EXCEPTION: Slopes not steeper than 1:48 shall be permitted.... 
- 
    
  
  305.2 Floor or Ground Surfaces
  Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.... 
- 
    
  
  11B-604.8.1.1 Size
  When deployed the baby changing tables shall not obstruct the required width of the accessible route except as allowed by Section 11B-307.2.... 
- Ronick Matting Systems BaseMat 300 Entrance Floor Mat
- 
    
  
  M303.3.3 Ramped (Section-by-Section Analysis)
  The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with... 
- 
    
  
  M303.3.3 Ramped
  Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.... 
- 
    
  
  M303.3.3 Ramped
  Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.... 
- 
    
  
  M303.3 Entry (Section-by-Section Analysis)
  This is an introductory section. 
- 
    
  
  1.1.9 Horizontal gaps and vertical alignment
  1.1.9 Horizontal gaps and vertical alignment. Measure for local horizontal discontinuities and variations in vertical alignment such as at concrete joints, gaps, grade breaks, and at... 
- 
    
  
  § 38.95(b)(8) Platform entrance ramp
  (8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches,... 
- 
    
  
  11B-604.8.1.1 Size
  This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap).... 
- 
    
  
  11B-604.8.1.1 Size
  This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap).... 