11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 11B-1005.2.1.1 Dispersion....
-
11B-1005.2.1.1 Dispersion
Railings, guards, or handrails required to comply with Section 11B-1005.2.1 shall be dispersed throughout the fishing pier or platform. Advisory 11B-1005.2.1.1 Dispersion....
-
11B-505.2 Where required
Handrails shall be provided on both sides of stairs and ramps....
-
11B-505.2 Where required
Handrails shall be provided on both sides of stairs and ramps. Exceptions: 1. ...
-
11B-505.2 Where required
Handrails shall be provided on both sides of stairs and ramps. Exceptions: 1. ...
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
11B-222.3 Mirrors
Where mirrors are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.6....
-
11B-222.3 Mirrors
Where mirrors are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.6....
-
11B-222.3 Mirrors
Where mirrors are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.6....
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within their...
-
Clearances between a handrail and wall surface: 2012 NFPA 101 vs. 2010 ADA
Question/Issue: According to the new 2012 NFPA 101 Life Safety Code, Chapter 7, Section 7.2.2.4.4.5 & Exhibit 7.97, the finger clearance at an existing stair handrail should be...
- Figure 505.6 Horizontal Projections Below Gripping Surface – Drawing from the U.S. Access Board
-
Aisle Stairs and Ramps in Assembly Areas
Sections 505.2 and 505.3 of the 2010 Standards provide exceptions for aisle ramp handrails....
-
Extremely well done!
Hello Corada, Thank you ETA and Dan for pointing me to this How-to video on measuring handrail extensions....
-
R409.6 Gripping Surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....