Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10. Exceptions: 1. Extensions...
Search Results "Exit Stairway"
Commonly Searched Documents
-
11B-505.10 Handrail extensions
-
505.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with 505.10. EXCEPTIONS: 1. Extensions shall not be required...
-
11B-505.10 Handrail extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10. Exceptions: 1. Extensions...
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADAS] 210.1 General. Interior and exterior stairs that are part of a means of egress shall comply with...
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADA Standards] 210.1 General. Interior and exterior stairs that are part of a means of egress shall comply...
-
11B-505.10 Handrail extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10. Exceptions: Extensions shall...
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-203 General exceptions
shall only be required to comply with Sections 11B-206.2.8, 11B-207.1, and 11B-215.3 and shall be designed and constructed so that individuals with disabilities can approach, enter, and exit...
-
F216 Signs
[See subsections ...]
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
11B-703 SIGNS
[See subsections ...]
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
703 Signs
Requirements for signs provide specifications for raised characters (703.2), braille characters (703.3), the height and location of signs with tactile characters (703.4), visual...
-
Mounting Height and Location
Section 703.4 covers the mounting height and location of signs with tactile characters. Such signs are to be mounted so that the tactile elements (raised characters and braille) are...
-
703 Signs
[See subsections ...]
-
216 Signs
Scoping requirements for signs cover room designations (216.2) and directional and informational signs (216.3). The guidelines also include provisions specific to certain elements...
-
703 Signs
[See subsections ...]
-
216 Signs
[See subsections ...]
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
VI. Interior Signs...
[See subsections ...]
-
216 Signs
216 Signs