Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....
Search Results "Compartment Door"
-
4.23.2 Doors
-
4.23.2 DOORS
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....
-
604.8.1.4 Toe Clearance
Compartments for children's use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force. ...
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). gg....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADA Standards] 404.2.9 Door and Gate Opening Force....
-
604.8.1.4 Toe Clearance
Compartments for children’s use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor....
-
604.8.1.4 Toe Clearance
Compartments for children’s use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor....
-
11B-604.8.1.4 Toe clearance
Compartments for children’s use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor....
-
11B-604.8.1.4 Toe clearance
Compartments for children’s use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor....
-
2010 ADA Standards - Plan Review Tool - Doors
2010 ADA Standards - Plan Review Tool - Doors Click here to view/download the pdf, Page 1 of 2 (258 KB) Click here to view/download the pdf, Page 2 of 2 (264 KB) * * * * * * *...
-
4.3.9 DOORS
Doors along an accessible route shall comply with 4.13....
-
4.3.9 Doors
Doors along an accessible route shall comply with 4.13....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Doors
[See subsections ...]
-
11B-604.2 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-605.5.2 Maneuvering clearance
A turning space complying with Section 11B-304 shall be provided within the compartment....
-
11B-605.5.2 Maneuvering clearance
A turning space complying with Section 11B-304 shall be provided within the compartment....
-
11B-604.2 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
11B-604.2 Location
side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...