Search Results "Affiliate Transfers"
Commonly Searched Documents
- Figure 1008.3.2 Transfer Steps – Drawing from the U.S. Access Board
-
RECOMMENDED CHANGE
RECOMMENDED CHANGE Revise the Section 5.4.11 recommendation as follows: The Committee recommends transfer supports and connections contain the strength to resist vertical forces of...
-
5.1 Transfer Surface Height Recommendations
5.1 Transfer Surface Height Recommendations Description: The transfer height is set above the finished floor surface to permit transfers form mobility devices onto the transfer surface...
-
5.1 Transfer Surface Height
5.1 Transfer Surface Height...
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height...
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
M302.2.2 Sunset
The low transfer position height, Item A of M302.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. [sic]...
-
5.1.4 Transfer Surface Height Measurement
5.1.4 Transfer Surface Height Measurement....
-
Swimming Pools: ADA Standard Section 242.2
Section 242.2 covers scoping requirements in the current ADA Standards for swimming pools.
-
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment....
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-242.2 Swimming pools
Accessible means of entry shall be swimming pool lifts complying with Section 11B-1009.2; sloped entries complying with Section 11B-1009.3; transfer walls complying with Section 11B-1009.4...
-
Summary of Recommendations
Summary of Recommendations
-
Bathtubs (ADAAG 4.20)
Bathtubs (ADAAG 4.20) ADA Accessibility Guidelines for bathtubs are predicated on the use of a conventional residential bathtub by individuals who independently transfer from a wheelchair...
-
Width and Length
Width and Length Transfer walls must be a minimum of 12 inches wide to a maximum of 16 inches wide....
-
Highest and Lowest Heights Obtained
These data represent the ability of the participants in the study to complete a transfer....
-
§ 36.302(f)(6) Ticket transfer
(6) Ticket transfer....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
5.3.2 Transfer Sides Recommendations for M301
5.3.2 Transfer Sides Recommendations for M301 Description: The transfer side provision requires the transfer surface to be located to provide options to transfer onto the short side and...