Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
Search Results "Unobstructed Reach"
Commonly Searched Documents
-
Obstructed High Reach: ADA Standard Section 308.3.2
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
407.8.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches...
-
407.12.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches...
-
Side Reach: ADA Standard Section 308.3
Section 308.3 covers the current ADA Standards for side reach.
-
Side Reach [§308.3]
Side Reach [§308.3] The range for side reach, like forward reach is 15” to 48” if unobstructed....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
407.8.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm)...
-
407.12.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm)...
- Figure 308.3.1 Unobstructed Side Reach – Drawing from the U.S. Access Board
-
Forward Reach: ADA Standard Section 308.2
Section 308.2 covers the current ADA Standards for forward reach.
-
Reach Ranges: ADA Standard Section 308
Section 308 covers the current ADA Standards for reach ranges.
-
308.2 Forward Reach
308.2 Forward Reach...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.2.5* Forward Reach
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
Reach Ranges and Operability Requirements
Design Tip Understand forward reach and side reach terminology....
-
4.3 Reach Ranges
Australia Canada UK Unobstructed High Forward Reach...
-
4.34.3(2)(a) Reach Depth Not More Than 10 in
(a) Reach Depth Not More Than 10 in (255 mm)....
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....