Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
Search Results "Powder Room"
-
11B-809.10.8.1 Location
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section....
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section....
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section....
- Visitability
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
Number of Accessible Bathrooms
A few commenters recommended that half-baths/powder rooms also be subject to the Act's requirement. Response....
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor. Where towel bars are provided they shall be...
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section. 1. Floor space and location....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
Toilet and Bathing Rooms: ADA Standard Section 805.4
Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603....