5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
Search Results "Positioning Support"
Commonly Searched Documents
-
5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
-
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment
Instead, positioning supports should be required....
-
5.9.1 Standing Supports In Reference To Mammography Equipment
5.9.1 Standing Supports In Reference To Mammography Equipment. The requirement for standing supports should be removed for mammography equipment....
-
5.9 Standing Support for Equipment Used by Patients in a Standing Position
5.9 Standing Support for Equipment Used by Patients in a Standing Position....
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the transfer...
-
5.4.1.1 Transfer Support Location Recommendation for Stretchers
5.4.1.1 Transfer Support Location Recommendation for Stretchers For Stretchers, the transfer surface is oriented along the long side of the surface....
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position Description: Many people who ambulate with a disability need support to maintain...
-
5.5.1 Armrest Provision for Equipment Used by Patient in Seated Position
5.5.1 Armrest Provision for Equipment Used by Patient in Seated Position. Armrests are not required but if provided cannot obstruct transfer supports....
-
11B-407.4.10 Support rail
Support rails shall be provided on at least one wall of the car. Advisory 11B-407.4.10 Support rail....
-
11B-903.4 Back support
Back support shall be 2½ inches (64 mm) maximum from the rear edge of the seat measured horizontally. [2010 ADA Standards] 903.4 Back Support....
-
5.4.2.1 Transfer Support Length Recommendation for Stretchers
5.4.2.1 Transfer Support Length Recommendation for Stretchers On Stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are positioned...
-
Location and Size
supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated position: • At least one transfer support would be provided on the side of the transfer surface...
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that transfer supports must be provided for use with transfer sides on diagnostic equipment used by patients in the seated position, and that these...
-
1. Standing Supports
position....
-
M305.5 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
5.4.1.1 Transfer Support Location for Stretchers
5.4.1.1 Transfer Support Location for Stretchers. The transfer surface for stretchers should be oriented along the long side of the surface....
-
M302.3 Supports
Transfer supports, leg supports and reclining surfaces shall comply with M302.3....
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5....
-
M305.2 Transfer Supports
M305.2 Transfer Supports M305.2.2 Transfer Supports Structural Strength Proposed requirement: Transfer supports and their connections shall be capable of resisting vertical and...
-
M302.3 Supports
Transfer supports, armrests, and reclining surfaces shall comply with M302.3....
-
M305.3.2.1 Horizontal Position
The height of the top of the gripping surface on horizontal standing supports shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface....
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply with M305.3.1.2...