(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that...
Search Results "Elevator Building"
-
7(1)(c)
-
7(2) Usable bathrooms
(2) Usable bathrooms. To meet the requirements of section 100.205(c)(3)(iv) either: All bathrooms in the dwelling unit comply with the provisions of paragraph (a); or At least...
-
7(2)(a)
(a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the...
-
Site Impracticality Determinations
connection with the construction of a high rise elevator building generally results in a finished grade that would make the building accessible....
-
Changes in Level within a Dwelling Unit
buildings be equipped with internal elevators, chair lifts, or other means of access to the upper levels (55 FR 24377)....
-
Guidelines for Requirement 5
The Guidelines for Requirement 5 present design specifications for providing dwelling units that contain light switches, electrical outlets, thermostats, and other environmental...
-
Guidelines for Requirement 7
The Guidelines for Requirement 7 present design specifications for providing usable kitchens and bathrooms such that an individual in a wheelchair can maneuver about the space, as...
-
11B-233.3.1.2 Residential dwelling units with adaptable features
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect....
-
11B-233.3.1.2 Residential dwelling units with adaptable features
In buildings with three or more residential dwelling units, adaptable residential dwelling units complying with Sections 11B-809.6 through 11B-809.12. shall be provided as required by Sections...
-
11B-233.3.1.2 Residential dwelling units with adaptable features
In buildings with three or more residential dwelling units, adaptable residential dwelling units complying with Sections 11B-809.6 and shall be provided as required by Sections 11B-233.3.1.2.1...
-
11B-233.3.1.2.1 Elevator buildings
A residential building with one or more elevators shall have an elevator serve all floors with a residential dwelling unit primary entrance and all floors with common use areas....
-
11B-233.3.1.2.1 Elevator buildings
A residential building with one or more elevators shall have an elevator serve all floors with a residential dwelling unit primary entrance and all floors with common use areas....
-
11B-233.3.1.2.1 Elevator buildings
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
conditions or unusual characteristics: All ground floor units in non-elevator buildings shall be adaptable and on an accessible route unless an accessible route to the common (lobby)...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
conditions or unusual characteristics: All ground floor units in non-elevator buildings shall be adaptable and on an accessible route unless an accessible route to the common (lobby)...
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
conditions or unusual characteristics: All ground floor units in non-elevator buildings shall be adaptable and on an accessible route unless an accessible route to the common (lobby)...
-
11.1 Q. Under the individual building test, how is the second step of the test performed, which involves measuring the slope of the finished grade between the entrance and applicable arrival points?
A. The slope is measured at ground level from the entrance to the top of the pavement of all vehicular and pedestrian arrival points within 50 feet of the planned entrance, or, if...
-
11.2 Q. Under the individual building test, at what point of the planned entrance is the measurement taken?
On a horizontal plane, the center of each individual doorway should be the point of measurement when measuring to an arrival point, whether the doorway is an entrance door to the building...
-
12.1 Q...How is the individual building test performed for additional stories, to determine if those stories must also be treated as ground floors?
For purposes of determining whether a non-elevator building has more than one ground floor, the point of measurement for additional ground floors, after the first ground floor has been established...
-
12.2 Q. What happens if a builder deliberately manipulates the grade so that a second story, which also might have been treated as a ground floor, requires steps?
A. Deliberate manipulation of the height of the finished floor level to avoid the requirements of the Fair Housing Act would serve as a basis for the Department to determine that...
-
Requirement 6 -- Reinforced Walls for Grab Bars