Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
Search Results "Edge Protection"
Commonly Searched Documents
-
11B-1005.3 Edge protection
-
Edge Protection [§405.9]
Edge Protection [§405.9] Edge protection along ramp runs and landings keep wheelchair casters and crutch tips on the surface and can be provided by curbs, barriers, or extended surfaces...
- Figure 405.9.2 Curb or Barrier Edge Protection – Drawing from the U.S. Access Board
-
4.8.7 Edge Protection
Ramps and landings with drop-offs shall have curbs, walls, railings, or projecting surfaces that prevent people from slipping off the ramp. Curbs shall be a minimum of 2 in (50 mm)...
-
4.8.7 EDGE PROTECTION
Ramps and landings with drop-offs shall have curbs, walls, railings, or projecting surfaces that prevent people from slipping off the ramp. Curbs shall be a minimum of 2 in (50 mm)...
-
11B-405.9.2 Curb or barrier
FIGURE 11B-405.9.2 ‡‡ CURB OR BARRIER EDGE PROTECTION ETA Editor's Note 2013 CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the...
-
405.9.2 Curb or Barrier
[ECTCR UFAS 4.8.7] Figure 405.9.2 Curb or Barrier Edge Protection...
-
405.9.2 Curb or Barrier
Figure 405.9.2 Curb or Barrier Edge Protection...
-
11B-405.9.2 Curb or barrier
ETA Editor's Note CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface also permitted by 2010 ADAS....
-
11B-405.9.2 Curb or barrier
[Safe Harbor 11B-405.9.2] ETA Editor's Note CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface...
-
11B-405.9.1 Reserved
11B-405.9.1 Reserved. [2010 ADAS] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond...
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face...
-
Curb or Barrier: ADA Standard Section 1005.3.1
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.
-
4g.
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Stds 4.8.7] Yes _____ No _____...
-
Error/Omission: Parts of an accessible route with slopes that exceed 1:20 lack required features including handrails and edge protection.
Error/Omission: Parts of an accessible route with slopes that exceed 1:20 lack required features including handrails and edge protection....
-
d-vii
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Standards § 4.8.7] Yes No...
-
5.7 Raised Platforms
Open edges of a raised platform shall be protected by placement of tables or by a curb....
-
6.12 Handrails and Edge Protection
Where elevated dune crossings or dune crossings steeper than 1:20 (5 percent) are part of beach access routes, handrails complying with ABAAS section 505 and edge protection complying...
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or...
-
R407.9.2 Curb or Barrier
R407.9.2 Curb or Barrier. A curb or barrier shall be provided that prevents the passage of a 100 mm (4 in) diameter sphere, where any portion of the sphere is within 100 mm (4 in) of...
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or...