In areas of refuge, exterior areas for assisted rescue and locations required to provide two-way communications systems complying with Section 1009.8, instructions on the use of the area...
Search Results "Area of Rescue Assistance"
-
1009.11 Instructions
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1007.7.5 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1007.7.4 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.9 Signage
sign stating, "AREA OF REFUGE."...
-
1009.9 Signage
sign stating: "AREA OF REFUGE"....
-
Areas of Rescue Assistance [4.1.3(9), 4.3.11]
Areas of rescue assistance are fire-rated spaces where people unable to use stairs can await evacuation assistance from emergency personnel....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
4.3.11.1(1)
(1) A portion of a stairway landing within a smokeproof enclosure (complying with local requirements).
-
1007.8.3 Identification
Exterior areas for assisted rescue shall have identification as required for area of refuge that complies with Section 1007.6.5....
-
1003.2.13.7.1 Openness
The exterior area of refuge shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
1007.7.3 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1007.6.1....
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.9 at doors to areas of refuge and exterior areas for assisted rescue shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5...
-
4.3.11.1(3)
(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit...
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1007.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_....
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_....