of Refuge (Area of Refuge) requirements as specified by the US ADA Act....
Search Results "Area of Refuge"
- ADA-100® Area of Refuge Communication System
-
216.4.2 Areas of Refuge
216.4.2 Areas of Refuge....
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that rescue...
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that rescue...
-
1009.6.3 Size
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
-
1009.6.3 Size
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
-
F216.4.2 Areas of Refuge
Code (2000 edition) or section 1007.6.4 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1) to provide instructions in areas...
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2....
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
1007.6 Areas of refuge
1007.6 Areas of refuge. Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
1009.11 Instructions
In areas of refuge, exterior areas for assisted rescue and locations required to provide two-way communications systems complying with Section 1009.8, instructions on the use of the area...
-
Is There a Usable Circulation Path?
A person with disabilities is able to travel unassisted through that portion of the circulation path necessary to reach an area of refuge....
-
Is There a Usable Circulation Path?
A person with disabilities is able to travel unassisted through that portion of the circulation path necessary to reach an area of refuge....
-
Circulation Path
A person with disabilities is able to travel unassisted through that portion of the circulation path necessary to reach an area of refuge....
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
1009.6.2 Stairway or elevator access
Every required area of refuge shall have direct access to a stairway complying with Sections 1009.3 and 1023 or an elevator complying with Section 1009.4....
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....
-
1009.6.4 Separation
Each area of refuge shall be designed to minimize the intrusion of smoke....
-
1009.6.4 Separation
Each area of refuge shall be designed to minimize the intrusion of smoke. Exceptions: 1....
-
1007.6.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709 or a horizontal exit complying with Section 1025....