There is an official review and approval process under the ADA only for transportation facilities (and vehicles) subject to DOT’s ADA regulations, which establish a process for determining...
Search Results "Approved"
-
Is there an official review and approval process under the ADA for alternatives pursued as an “equivalent facilitation”?
-
DSA IR A-10: ALTERATION AND RECONSTRUCTION PROJECTS—DSA APPROVAL EXEMPTION (with revisions issued through Jan. 2018)
IR A-10: ALTERATION AND RECONSTRUCTION PROJECTS—DSA APPROVAL EXEMPTION Disciplines: Structural Fire & Life Safety...
-
SUBCHAPTER C. REVIEW AND APPROVAL REQUIRED FOR CERTAIN PLANS AND SPECIFICATIONS
[See subsections ...]
-
1.1.9 Effective date of this code
Only those standards approved by the California Building Standards Commission that are effective at the time an application for building permit is submitted shall apply to the plans and...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per Chapter 1,...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per Chapter 1,...
-
104.11 Alternative materials, design and methods of construction and equipment
intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved...
-
1.2.3 Alternative materials, design and methods of construction and equipment
intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved...
-
1.2.3 Alternative materials, design and methods of construction and equipment
intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved...
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department. ...
-
11B-703.1.1.1 Plan review
Plans, specifications or other information indicating compliance with these regulations shall be submitted to the enforcing agency for review and approval....
-
11B-703.1.1.1 Plan review
Plans, specifications or other information indicating compliance with these regulations shall be submitted to the enforcing agency for review and approval....
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department....
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
PERMIT
In State-funded construction, a letter following plan review which approves the plans and allows the release of funds is equivalent to a "permit.” ◼...
-
PERMIT
In State-funded construction, a letter following plan review which approves the plans and allows the release of funds is equivalent to a "permit.” ◼...
-
1009.10 Directional signage
the other means of egress and which of those are accessible means of egress shall be provided at the following: At exits serving a required accessible space but not providing an approved...
-
1009.10 Directional signage
all other means of egress and which of those are accessible means of egress shall be provided at the following: At exits serving a required accessible space but not providing an approved...
-
702.6.1 ICC A117.1-2009
Accessible and Usable Buildings and Facilities, approved October 20, 2010, IBR approved for Appendix C, Section 402.5....
-
[A] 104.11 Alternative materials, design and methods of construction and equipment
intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved...
-
1.9.1.4 Enforcing agency
For accessibility, in State-funded tenant improvements to State-leased facilities, the local jurisdiction must be aware of DGS’ jurisdictional authority and DSA’s jurisdictional approvals...
-
1.9.1.4 Enforcing agency
For accessibility, in State-funded tenant improvements to State-leased facilities, the local jurisdiction must be aware of DGS’ jurisdictional authority and DSA’s jurisdictional approvals...
-
E. Paperwork Reduction Act
The Department will pursue OMB approval for this requirement during the year between the publication and effective dates of the rule....