[2010 ADAS] 216.7 Elevators. ...
Search Results "ADA Compliance"
Commonly Searched Documents
-
11B-216.7 Elevators
-
11B-405.7.5 Doorways
[2010 ADAS] 405.7.5 Doorways....
-
11B-404.3.1 Clear width
[2010 ADAS] 404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
11B-225.2.3 Library book stacks
ETA Editor's Note The ADA Advisory identifies library shelving as self-service shelving, which does not have a height limitation....
-
11B-404.3.1 Clear width
[2010 ADA Standards] 404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
11B-216.7 Elevators
[2010 ADA Standards] 216.7 Elevators....
-
11B-219.3 Receivers
[2010 ADA Standards] 219.3 Receivers. Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
11B-502.3.3 Marking
[2010 ADA Standards] 502.3.3 Marking. Access aisles shall be marked so as to discourage parking in them. Advisory 11B-502.3.3 Marking....
-
5. Conforming Alternate Versions
., the ADA implementing regulation for title II at 28 CFR 35.130(b)(1)(iii) and (iv) and 35.130(b)(8)(d), and the ADA implementing regulation for title III at 28 CFR 36.202(b) and (c), and...
-
Confidentiality
medical examinations and inquiries must be kept apart from general personnel files as a separate, confidential medical record, available only under limited conditions specified in the ADA...
-
Obtaining, Using, and Disclosing Medical Information
OBTAINING, USING, AND DISCLOSING MEDICAL INFORMATION Title I of the ADA limits an employer's ability to ask questions related to hearing and other disabilities and to conduct medical...
-
D5
[ADA Standards §§ 4.1.6(3)(d)(ii), 4.13.8] Yes No If No, replace threshold with one with beveled sides or add a sloped insert....
-
K4
[ADA Standards § 5.5] Yes No...
-
M5
[ADA Standards §§ 4.1.6(3)(d)(ii); 4.13.8] Yes No If No, replace threshold with one with beveled sides or add a sloped insert....
-
3. Folding Seat
[ADA Stds. 4.21.3] Yes __ No __ N/A __ Comments: _______________________________________...
-
8. Pipe Insulation
[ADA Stds. 9.2.2(6)(e); 4.23.6; 4.19.4] Yes __ No __ N/A __ Comments: _____________________________________...
-
Jamb Signage
[ADA Stds. 4.10.5] Yes __ No __ N/A __ Comments: ___________________________________________...
-
1c
[ADA Standards 4.21.2] Yes __ No __ N/A __ Comments: ________________________________________...
-
Flange way gap
(DOT ADA Standard 810.10.)...
-
I1a
[ADA Standards § 4.31.2, Fig. 44 (a)] Yes No...
-
D4
[ADA Standards § 4.13.6, Fig. 25] Yes No If No, leave the door propped open or find another accessible entrance....
-
11B-708.2 Audible and visual indicators
[2010 ADAS] Advisory 708.2 Audible and Visual Indicators. A light can be used to indicate visually that assistance is on the way....
-
5e.
[ADA Stds 4.10.5] Yes _____ No _____...
-
Stability or Stable Surface
A stable surface is one that remains unchanged by contaminants or applied force, so that when the contaminant or force is removed, the surface returns to its original condition (2010 ADA...