Accessibility: ADA Compliant Model(s) Available Material: Stainless Steel Mount: Floor Mounted Against Wall Environmental/Health: Contains Recycled Material , Recyclable , Water...
Search Results "Ground Floor Exit"
Commonly Searched Documents
- Neo-Metro Commercial Metaal Toilet 8956 Series
- Neo-Metro Contour Commercial Stainless Steel Toilet 8955 Series
-
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators
They require passengers to enter their destination floor on an entry device, usually a keypad, in the elevator lobby....
-
Knee and Toe Clearance (M303.2.4)
5 inches deep maximum at 14 inches above the floor Knee Clearance 11 inches deep minimum at 9 inches above the floor, and 8 inches deep minimum at...
-
Can parking signage height be considered a "safe harbor"?
Signs designating parking places for disabled people can be seen from a driver’s seat if the signs are mounted high enough above the ground and located at the front of a parking space....
-
Benches
Benches must have a clear floor space positioned to allow persons using wheelchairs or other mobility devices to approach parallel to the short end of a bench seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
233.4.1
233.4.1 In sleeping rooms with more than 25 beds, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3....
-
409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions....
-
2. Rear grab bar
Rear grab bar: There is a grab bar behind the toilet that is at least 36 inches long and from 33 to 36 inches above the floor....
-
707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
6. Toilet Seat
Is the toilet seat in each accessible toilet room between 17"-19" above the floor? [ADA Stds. 4.16.3] Yes __ No __ N/A __ Comments: _____________________________________...
-
H28
Is the surface of the toilet seat in this 36-inch-wide stall 17 to 19 inches above the floor? [ADA Standards §§ 4.16.3; 4.22.4] Yes No...
-
6e.
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach? Yes _____ No _____...
-
4.19.6* Mirrors
Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015 mm) above the finish floor (see Fig. 31)....
-
4.10.4(1)
(1) Hall lantern fixtures shall be mounted so that their centerline is at least 72 in (1830 mm) above the lobby floor. (See Fig. 20.)...
-
4.18.4 FLUSH CONTROLS
Flush controls shall be hand operated or automatic, and shall comply with 4.27.4, and shall be mounted no more than 44 in (1120 mm) above the floor....