Current accessibility standards include criteria related to seat height, clear floor space, and grab bar placement in places where transfers are expected [7]....
Search Results "Floor Surface"
-
Background
- Inpro ENDURANT® Shower Receptors
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
Buttons: ADA Standard Section 407.4.6.2
Section 407.4.6.2 covers the current ADA Standards for the elevator car control buttons.
-
Leveling: ADA Standard Section 409.4.4
Section 409.4.4 covers the ADA Standards for the self-leveling feature in private residence elevators.
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
412.2.6 Accessibility
[DSA-AC] In air traffic control towers, an accessible route shall not be required to serve the cab and the equipment areas on the floor immediately below the cab....
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
Tray Slides: ADA Standard Section 904.5.2
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
412.2.6 Accessibility
[DSA-AC] In air traffic control towers, an accessible route shall not be required to serve the cab and the equipment areas on the floor immediately below the cab....
-
Visibility: ADA Standard Section 707.7.1
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Grab Bars: ADA Standard Section 1009.5.7
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Standard Stall
Recommendation: Ceiling-mounted partitions are a good idea because toe clearance is not interrupted by vertical supports [sic] Because floor-mounted toilets commonly project further...
-
Alterations To An Area Containing A Primary Function
include, but are not limited to – §36.403(c)(1)(i) Remodeling merchandise display areas or employee work areas in a department store; §36.403(c)(1)(ii) Replacing an inaccessible floor...
-
Location
An accessible route never has curbs or stairs, must be at least 3- feet wide, and has a firm, stable, slip-resistant surface....
-
Signage
are provided for all permanent rooms and spaces in the lodging facility must be mounted on the wall (not the door) adjacent to the latch side of the door and centered 60 inches above the floor...
-
Location
An accessible route never has curbs or stairs, must be at least 3- feet wide, and has a firm, stable, slip-resistant surface....