Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
Search Results "Door Clear Width"
Commonly Searched Documents
-
Character Proportions: ADA Standard Section 703.5.4
-
3306.2 Walkways
Walkways shall be of sufficient width to accommodate the pedestrian traffic, but shall be not less than 4 feet (1219 mm) in width....
-
1010.2.13.1 Delayed egress locking system
Initiation of the irreversible process shall activate an audible signal in the vicinity of the door....
-
Table 1
requirements are the same. 24The requirements analyzed in Table 1 include: drinking fountains, public toilet facilities, tables, counters, passenger loading zones, ramps, stairways, handrails, doors...
-
201.1 Scope
commercial facility or public accommodation extends to those elements used to enter the commercial facility or public accommodation, including the homeowner´s front sidewalk, if any, the door...
-
KEEP Clear of WheelChair Ramps Video
Requires the Registered User plan or above. Login!
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
Handrails: ADA Standard Section 1009.6.2
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
Boating facilities. (Section-by-Section Analysis)
In existing boarding piers, the required clear pier space may be perpendicular to and extend the width of the boat slip if the facility has at least one accessible boat slip, providing that...
-
Design Criteria for the Transfer Station
The station was designed to investigate the impact handhelds, back rests, heights, and seat widths have on transfer performance....
-
Boating facilities. (Section-by-Section Analysis)
In existing boarding piers, the required clear pier space may be perpendicular to and extend the width of the boat slip if the facility has at least one accessible boat slip, providing that...
-
4.9.4 HANDRAILS
Figure 19 Stair Handrails (2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
9.2.2(7) Kitchens, Kitchenettes, or Wet Bars
Clear floor space for a front or parallel approach to cabinets, counters, sinks, and appliances shall be provided to comply with 4.2.4....
-
304.2 Floor or Ground Surfaces
Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park...
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
1134A.7 Water closets
The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
Where Required: ADA Standard Section 505.2
Section 505.2 covers the current ADA Standards for where handrails are required.
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
Technical Requirements for Accessible Hiker/Pedestrian Trails
Section 7.4 of FSTAG explains the accessibility requirements for trails, including trail surfacing, clear tread width, grade and cross slope, resting intervals, passing spaces, tread obstacles...
-
Accessibility Evaluation Surveys
For example, check doorways to see whether they have at least 32 inches (815 millimeters) of clear width (figure 14)....
-
304.2 Floor or Ground Surfaces
Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park...
-
11B-304.2 Floor or Ground Surfaces
Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park...
