Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
Search Results "Curb Ramp Surface"
-
11B-307.3.1 Edges and corners
-
Dome Spacing: ADA Standard Section 705.1.2
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
- Detectable Warning Systems, Inc. AlertTile® Detectable Warning
-
Check-out Aisle Counter Height
The counter surface of check-out aisle counters is required to be 38 inches high maximum. Comments from persons with disabilities considered 38 inches to be too high. Response....
- Accessible Mats for Beach and Outdoor Events
-
Delimitations
following: Data from this study were obtained from a longitudinal study administered through the National Center on Accessibility (NCA) at Indiana University; One category of surface...
-
APPENDIX B
OUTSIDE SURFACES Figure 27: Pictures and Roughness Index of Outside surfaces...
-
5.1 Tell the Doctor and the Staff
Or you could say, “There isn’t a curb cut onto the sidewalk from the accessible parking and I had to roll in the street for a block.”...
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular to the curb...
-
Recommendations for Further Action
are available for use on pedestrian trails and how various surface materials perform in different regions of the country....
-
1009.2.1 Elevators required
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp...
-
11B-108 Maintenance of accessible features
It is not sufficient to provide features such as accessible routes, parking, elevators, ramps or signage if those features are not maintained in a manner that enables individuals with disabilities...
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps. 3....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps....
-
Tactile Symbols: ADA Standard Section 707.6.3.2
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
Dome Size: ADA Standard Section 705.1.1
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing surface...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing surface...
-
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or Other Mobility Devices
Where ramps are used, they cannot be steeper than 1:12. Ramps with a vertical rise of more than 6 inches must have handrails on both sides....