Clear floor space for either a forward or side approach is allowed....
Search Results "Clear Width at Turn"
-
Storage [9.2.2(4)]
-
Constructed Features in Recreation Sites
replaced, but the ground under the feature isn't changed, the surface and slope of the ground under the feature doesn't have to be brought into conformance with accessibility requirements for clear...
-
R402.3 Post-Mounted Objects
Where objects are mounted between posts or pylons and the clear distance between the posts or pylons is greater than 305mm (1.0 ft), the lowest edge of the object shall be 685 mm (2.25 ft...
-
11B-707.3 Operable parts
Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation. Exceptions: 1....
-
11B-307.3 Post-mounted objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
11B-307.3 Post-mounted objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
E205.1 General (Section-by-Section Analysis)
In turn, proposed E205 requires conformance to the Level A and Level AA Success Criteria and Conformance Requirements specified for Web pages in WCAG 2.0 or ISO 14289-1 (PDF/UA-1), both...
-
11B-704.3 Volume control telephones
If the microphone in the handset is not being used, a mute button that temporarily turns off the microphone can also reduce the amount of background noise which the person hears in the earpiece...
-
Sides of Curb Ramps
Otherwise, maneuvering at the top of ramps would require turning on the flared sides. Landings must also be as wide as the curb ramp they serve....
-
2. Typical Issues for Individuals Who Are Blind or Have Low Vision
The bottom of the handrail extensions turn down to 27 inches or less above the route so a person who is blind or has low vision can detect the hazard before running into it. 2....
-
Part 2. Typical Issues for Voters Who Are Blind or Have Low Vision
The bottom of the handrail extensions turn down so a person who is blind or has low vision can detect the hazard before running into it. 2....
-
III-3.7000 Maintenance of accessible features
ILLUSTRATION 1: It would be a violation for a building manager of a three-story building to turn off an elevator during business hours in order to save energy....
-
11B-704.3 Volume control telephones
If the microphone in the handset is not being used, a mute button that temporarily turns off the microphone can also reduce the amount of background noise which the person hears in the earpiece...
-
3. Maintenance of Accessible Features
Although temporary interruptions in services due to bad weather are expected, alternate services should be provided if snow and ice cannot be cleared in a timely manner....
-
Foot Travel on Trails and Roads With Restrictions
Department of Agriculture has determined that a minimum of 36 inches (915 millimeters) of clear passage must normally be provided around or through the gate, berm, or other restrictive device...
-
Camping Units
The minimum size of a camp living area is determined by the type and number of constructed features provided and the required clear space around each feature....
- Open Future Learning
- Assisted Living Directory - Idaho Assisted Living Facilities & Senior Care
- Assisted Living Directory - Nevada Assisted Living Facilities & Senior Care
-
[2010 ADAS] 105.2.3 ASTM
When a surface is tested it must have an average work per foot value for straight propulsion and for turning less than the average work per foot values for straight propulsion and for turning...
-
ASTM
When a surface is tested it must have an average work per foot value for straight propulsion and for turning less than the average work per foot values for straight propulsion and for turning...
- Panda TS.83 Thermally Broken Multi-Slide Door System
- Panda UTS.60 Thermally Broken ULTRA Folding Door System
-
Re: Section 307 Protruding Objects
The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance...