Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
Search Results "Ground Floor"
-
802.1.4 Approach
-
Protruding objects and vitrines
aprons, extend bases, or add barriers below objects and vitrines that project more than 4" from walls and have their leading edges greater than 27" and less than 80" above the finished floor...
-
4.17.6 Grab Bars
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
4.30.3 Character Height
Height Above Finished Floor Minimum Character Height Suspended or Projected Overhead in compliance with 4.4.2 3 in (75mm) minimum...
-
4.17.6 GRAB BARS
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
§ 38.107(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.123(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.23(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch....
-
5.8.2.7 Base Support Allowance Recommendation
of 4 inches above the floor at a depth of 28 inches from the front edge of the breast platform....
-
Re: Section 307 Protruding Objects
The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211. ...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
- Trench Drain SSB 5038TR .75 Base
-
Hand Cycles (Stand-Alone)
The caster wheels do not touch the ground unless the rider leans the bicycle to one side or the other....
-
§ 38.83(b)(2)(i) Requirements
., ground, curb, and intermediate positions) normally encountered in the operating environment....
-
§ 38.23(b)(2)(i) Requirements
., ground, curb, and intermediate positions) normally encountered in the operating environment....
-
§ 38.159(b)(2)(i) Requirements
., ground, curb, and intermediate positions) normally encountered in the operating environment....