designated stops have boarding platforms and the design of boarding platforms and non-rail vehicles are coordinated to provide boarding having little or no change in level between the vehicle floor...
Search Results "Ground Floor"
-
Level boarding bus system
-
Signage (slide 11)
They really should be solid at floor level, and, not shadowed, as you [lean in to read]. Auditory signs can be an option....
-
407.8.2.1 Unobstructed Side Reach
part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
408.2 Visibility
Where stationary ICT provides one or more display screens, at least one of each type of display screen shall be visible from a point located 40 inches (1015 mm) above the floor space where...
-
408.1 General
Where stationary ICT provides one or more display screens, at least one of each type of display screen shall be visible from a point located 40 inches (1015 mm) above the floor space where...
-
Automatic Door
The switch that begins the automatic cycle may be a photoelectric device, floor mat, or manual switch (see power-assisted door)....
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
Laser scanners
These types of instruments could be used to measure floor flatness and level but they are very expensive, require training, and give accuracies in excess of what is needed for accessible...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
, which can extend to a height of 4 inches above the floor at a depth of 28 inches....
-
11B-1003.2.1 Boat slips
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7. ...
-
Checklist for Inclusive Emergency Safety Briefings for Attendees
take any stairwell and exit at the ground floor, Incorporating slides and / or pictures in the briefing can increase attention and understanding for those...
-
Test Procedures
It has been correlated to the work measurement done in ASTM F1951, Accessibility of Surface Systems, for a wide array of surfacing and floor coverings....
-
DEFENDANTS’ RAISED PORCHES
The raised porches are accessed from the exterior of the stores by ascending two steps from ground level....
-
11B-1003.2.1 Boat slips
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms,...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
Height: ADA Standard Section 704.4.1