[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
Search Results "Fire-Building Surface"
-
WALK
-
11B-207.2 Platform lifts
Standby power shall be provided for platform lifts permitted by section 1003.2.13.4 of the International Building Code (2000 edition and 2001 Supplement) or section 1007.5 of the International...
-
11B-207.2 Platform lifts
Standby power shall be provided for platform lifts permitted by section 1003.2.13.4 of the International Building Code (2000 edition and 2001 Supplement) or section 1007.5 of the International...
-
Benches
Ensure that all benches provided along Forest Service trails or beach access routes or at Forest Service recreation sites (other than those inside a building or in an amphitheater) meet...
- Wilkinson Hi-Rise Trash Chute
-
4.29.3* TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
to areas that might prove dangerous to a blind person (for example, doors to loading platforms, boiler rooms, stages, and the like) shall be made identifiable to the touch by a textured surface...
-
Boarding Piers at Boat Launch Ramps
A boat launch ramp is a sloped surface designed for launching and retrieving trailered boats and other watercraft to and from a body of water....
-
Dome Spacing: ADA Standard Section 705.1.2
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
11B-505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
- Inpro Corporation ENDURANT® Ceiling Hung Partitions
- Inpro Corporation ENDURANT® Floor-Mounted Overhead-Braced Partitions
-
11B-705.1.1.4 Resiliency
Detectable warning surfaces shall differ from adjoining surfaces in resiliency or sound-on-cane contact....
-
1(3)(a)(ii)
(ii) If the building elevator is provided as a means of access to dwelling units other than dwelling units on a ground floor, then the building is an elevator building which is a covered...
-
Can People Who are Blind or Have Low Vision Use the Circulation Path by Themselves?
An area of refuge serves as a temporary haven from the effects of a fire or other emergency....
-
E2-1. Pedestrian Routes
Items to check include wall-mounted fire extinguishers, light fixtures, coat hooks, shelves, drinking fountains, and display cases....
-
Communication Features in Guest Rooms
The guidelines address rooms required to provide communication features accessible to persons who are deaf or hard of hearing, including visual notification of fire alarms, telephone calls...
-
Check-out Aisle Counter Height
The counter surface of check-out aisle counters is required to be 38 inches high maximum. Comments from persons with disabilities considered 38 inches to be too high. Response....
-
Issue 16: What environmental and perceptual data on artificial/electric lighting are available from buildings with low vision occupants?
Question by Jim Woods: I do have one more question for Eunice. Is this [RP 28-07 ANSI/IES Standard: Lighting and the Visual Environment for Senior Living] based on some hard data...
-
Delimitations
following: Data from this study were obtained from a longitudinal study administered through the National Center on Accessibility (NCA) at Indiana University; One category of surface...
-
Recommendations for Further Action
are available for use on pedestrian trails and how various surface materials perform in different regions of the country....
-
References
Advisory 304.2 Floor or Ground Surface Exception....
-
Tactile Symbols: ADA Standard Section 707.6.3.2
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...