Protruding objects are defined as constructed features such as signs that extend into the clear width area of a trail, resting interval, or passing space between 27 inches (685 millimeters...
Search Results "Clear Space"
-
Protruding Objects and Trails
-
Camping Units
The minimum size of a camp living area is determined by the type and number of constructed features provided and the required clear space around each feature....
-
1016.6 Openings
Spaces between the boards in a boardwalk and drainage grates are examples of openings. ...
-
604.8.1.6 Lavatory
The lavatory shall be mounted so as not to overlap the clear floor space areas required by section 604 for the wheelchair accessible toilet compartment and shall comply with section 606....
-
Controls
Clear floor space at controls should be located outside the door swing....
-
Controls [9.2.2(5)]
Controls [9.2.2(5)] All controls in accessible units, sleeping rooms, and suites must comply with 4.27, which provides specifications for clear floor space, height of operable controls...
-
1016.6 Openings
Spaces between the boards in a boardwalk and drainage grates are examples of openings....
-
Maneuvering Clearances at Doors [4.13.6]
Maneuvering Clearances at Doors [4.13.6] Pull-side clearance beyond the door swing provides space for a forward reach to door hardware....
-
ABA CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
4. ACCESSIBLE ELEMENTS AND SPACES: SCOPE AND TECHNICAL REQUIREMENTS
[See subsections ...]
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
Display Screens
floor space in front of the automated kiosk....
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
- Landscape Forms Inc. Washington Square Bench Collection
-
In-swinging Bathroom Doors
The commenter recommended that in-swinging doors be prohibited unless there is sufficient internal bathroom space, exclusive of the swing of the door, which allows either a five foot turning...
-
4.4 Equipment Barriers and Solutions
Barriers Solutions Simple/Low cost Involved / High cost Spaces between the equipment are too narrow Ask staff to move one of each type...
-
Utility Sinks
Utility sinks don't have to comply with these requirements if they're located in a space without a cook top or range....
- Kompan, Inc. Electronic Playgrounds ICON1012 Space Video
-
1008.4.3 Play Tables
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...