The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
Search Results "Grade 2 Braille"
-
§ 38.95(b)(13) Handrails
-
§ 38.125(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.83(b)(13) Handrails
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
Readily Achievable
In determining whether an action is readily achievable factors to be considered include – (1) The nature and cost of the action needed under this part; (2) The overall financial resources...
-
Check-Out Aisles: ADA Standard Section 227.2
Section 227.2 covers scoping requirements in the current ADA Standards for check-out aisles.
-
1.1.8.1 Findings and filings.
Exception: Hazardous building ordinances and programs mitigating unreinforced masonry buildings. 2....
-
Accessible Routes: ADA Standard Section 1002.2
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
11B-705.1.2.2.2.2 Two entrance/exit points
to provide a minimum 108 inches (2743 mm) wide turning space, as measured perpendicular to the curb, the depth of detectable warnings may be reduced to 24 inches (610 mm) minimum. 2....
-
11B-606.3 Height
lavatory in a toilet or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 606.3. 2....
-
11B-705.1.2.2.2.2 Two entrance/exit points
to provide a minimum 108 inches (2743 mm) wide turning space, as measured perpendicular to the curb, the depth of detectable warnings may be reduced to 24 inches (610 mm) minimum. 2....
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-606.3 Height
lavatory in a toilet or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 606.3. 2....
-
Water Play Components: ADA Standard Section 1008.2.3
accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6 shall not be required. 2....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Suspicious Minds Ramp
The handrail of the ramp leading to the exhibits is not at the required distance of 1 1/2" from the wall. See Standards § 4.8.5(3)....
-
§104.34(b) Nonacademic settings
providing or arranging for the provision of nonacademic and extracurricular services and activities, including meals, recess periods, and the services and activities set forth in §104.37(a)(2)...
-
24 CFR Part 8—Nondiscrimination Based on Handicap in Federally Assisted Programs and Activities of the Department of Housing and Urban Development (with amendments issued through Dec. 2007)
Source: 53 FR 20233, June 2, 1988, unless otherwise noted....
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of 2¼...
-
Public entity
Public entity means -- (1) Any State or local government; (2) Any department, agency, special purpose district, or other instrumentality of a State or States or local government; and...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
4.5.4 Gratings
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
3.2.4 Slope
The ground surface in all camp living areas shall have a slope of no more than 1:48 (2 percent) in any direction. Exception....
-
FAQ: How do I delete a Voices post?
Login to Corada and click on VOICES. 2. Locate your post and click the title to open it. 3....
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....