Under the current 1991 Standards, the requisite clearance space in single-user toilet rooms between and around the toilet and the lavatory does not permit these methods of transfer....
Search Results "Building Permit"
-
Water Closet Clearances
-
Water Closet Clearances
Under the current 1991 Standards, the requisite clearance space in single-user toilet rooms between and around the toilet and the lavatory does not permit these methods of transfer....
-
MAKING THE BUILT ENVIRONMENT ACCESSIBLE
However, they are used differently depending on whether a small business is altering an existing building, building a brand new facility, or removing architectural barriers that have existed...
-
REFERENCES:
California Code of Regulations (CCR) Title 24, Part 1, California Building Standards Administrative Code, Sections 4-306, 4-308, 4-309, 4-315, 4-336, 4-406 and 5-102 California Education...
-
206.2.4 Spaces and Elements
At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility which are otherwise connected...
-
Chapter 1 GENERAL INFORMATION
Most people will, at some time during their lives, have a disability, either temporary or permanent, that will limit their ability to move around inside or outside a building and to easily...
-
11B-216.6 Entrances
In existing buildings and facilities where not all entrances comply with Section 11B-404, entrances complying with Section 11B-404 shall be identified by the International Symbol of Accessibility...
-
Employee Parking Lot
Is there a difference between parking spaces marked or reserved for employees and parking spaces that are just in the back of the building, unmarked but intended for employees?...
-
11B-604.5.2 Rear wall
The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm) minimum due to the...
-
Section 36.404 Alterations: Elevator Exemption (Preamble, Section-by-Section Analysis)
This part does not require that an existing two story building that houses the professional office of a health care provider be altered for the purpose of providing elevator access....
-
Assembly Area
A building or facility, or portion thereof, used for the purpose of entertainment, educational or civic gatherings, or similar purposes....
-
F217.5 Shelves for Portable TTYs
Where a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and...
-
4. Seating Plans for Designed Theaters and Future Construction Theaters
for Future Construction Theaters attached as Appendix D to this Consent Order for compliance with ADA Standard 4.33.3, and §§ 221 and 802 of the ADA and ABA Accessibility Guidelines for Buildings...
-
217.5 Shelves for Portable TTYs
Where a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and...
-
Accessible Routes
Accessible Routes Accessible routes are continuous, unobstructed paths connecting all accessible elements and spaces of a building or facility on golf courses....
-
1.2.2
that the plans and specifications (1) contain no work that is regulated by the accessibility standards of Title 24, (2) contain no work that triggers accessibility upgrades to existing buildings...
-
1003.2.13 Accessible means of egress
Exception: Accessible means of egress are not required in alterations to existing buildings....
-
1(2)(b) Site impracticality due to unusual characteristics
An accessible route to a building entrance is impractical due to unusual characteristics of the site when:...
-
216.4.1 Exit Doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
4.1.7(2)(a)(i)
U.S.C. 470 f) requires that a Federal agency with jurisdiction over a Federal, federally assisted, or federally licensed undertaking consider the effects of the agency’s undertaking on buildings...
-
4.1.6(1)(h) Entrances
(h)* Entrances: If a planned alteration entails alterations to an entrance, and the building has an accessible entrance, the entrance being altered is not required to comply with 4.1.3(8...
-
4.1.3(17)(b)
other public telephones provided shall be equipped with a volume control and shall be dispersed among all types of public telephones, including closed circuit telephones, throughout the building...
-
4.8.2* Slope and Rise
Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as allowed in 4.1.6(3)(a) if space limitations prohibit the use...
-
Do basements count in determining a facility’s story count?
As defined in the Standards, a “story” pertains to those portions of buildings “designed for human occupancy included between the upper surface of a floor and upper surface of the floor...