Controls shall be located within one of the reach ranges specified in Section 11B-308.
Search Results "Elevator Car Assignment"
Commonly Searched Documents
-
11B-411.4.6.1 Location
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1.
-
11B-407.4.8.1.4 Reserved.
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
11B-407.4.8.1.4 Reserved
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2.
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
408.3 Elevator Doors
408.3 Elevator Doors. Elevator hoistway doors shall comply with 408.3....
-
PASSENGER ELEVATOR
[DSA-AC] See “Elevator, Passenger”....
-
ELEVATOR, PASSENGER
[DSA-AC] An elevator used primarily to carry passengers....
-
Elevators: ADA Standard Section 206.6
Section 206.6 covers scoping requirements in the most current ADA Standards for accessible routes to elevators.
- Elvoron LU/LA - Limited Use / Limited Application Hydraulic Elevator
-
407.4 Elevator Car Requirements
Elevator cars shall comply with 407.4....
-
407.4 Elevator Car Requirements
Elevator cars shall comply with 407.4....
-
Elevator Car Requirements [§407.4]
Elevator Car Requirements [§407.4] The ADA Standards specify the minimum car dimensions....
-
408.3 Elevator Doors
Elevator hoistway doors shall comply with 408.3....