Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
Search Results "Elevator Car Assignment"
-
11B-407.3.1 Type
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305....
-
11B-1006.3 Golf car passages
Golf car passages shall comply with Section 11B-1006.3....
-
11B-1006.3 Golf car passages
Golf car passages shall comply with Section 11B-1006.3....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1....
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1....
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1....
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1.
-
407.4.8.1 Visible Indicators
Visible indicators shall comply with 407.4.8.1.
-
407.4.8.1 Visible Indicators
Visible indicators shall comply with 407.4.8.1.
-
407.4.8.1 Visible Indicators
407.4.8.1 Visible Indicators. Visible indicators shall comply with 407.4.8.1.
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1.
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1.
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....