Ramp runs shall have a running slope not steeper than 1:12....
Search Results "Cross Slope"
Commonly Searched Documents
-
11B-406.2.1 Slope
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
Surface, Slope, and Openings [1011.2.2, 1011.2.3, and 1011.2.4]
When the surface of the clear ground space is constructed of concrete, asphalt, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
-
505.7 Cross Section
Handrail gripping surfaces shall have a cross section complying with 505.7.1 or 505.7.2....
-
505.7 Cross Section
Handrail gripping surfaces shall have a cross section complying with 505.7.1 or 505.7.2....
-
505.7 Cross Section
Handrail gripping surfaces shall have a cross section complying with 505.7.1 or 505.7.2....
- Figure 406.2 Counter Slope of Surface Adjacent to Curb Ramps – Drawing from the U.S. Access Board
-
1.1.4
1.1.4 A maximum overall design running slope for exterior accessible ramps of 7.5% (1:13.3 or 1:13) is recommended....
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
4.1.6(4)(a)
Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as shown in Table 2 if space limitations prohibit the use of a 1...
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed....
-
4.1.6(3)(a) Ramps
(a) Ramps: Curb ramps and interior or exterior ramps to be constructed on sites or in existing buildings or facilities where space limitations prohibit the use of a 1:12 slope or less may...
-
Changes in Level [4.5.2]
Changes in level ¼ to ½ inch must be beveled with a slope no greater than 1:2....
-
A4.8.1 General
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
A4.8.1 GENERAL
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance...
-
4.1.6(3)(a)(i)
(i) A slope between 1:10 and 1:12 is allowed for a maximum rise of 6 inches....
-
11B-505.7 Cross section
Handrail gripping surfaces shall have a cross section complying with Section 11B-505.7.1 or 11B-505.7.2....
-
11B-505.7 Cross section
Handrail gripping surfaces shall have a cross section complying with Section 11B-505.7.1 or 11B-505.7.2....
-
11B-505.7 Cross section
Handrail gripping surfaces shall have a cross section complying with Section 11B-505.7.1 or 11B-505.7.2....
-
1017.7.1 Maximum Running Slope and Segment Length
The running slope of any segment of a trail shall not be steeper than 1:8 (12%). ...
-
1017.7.1 Maximum Running Slope and Segment Length
The running slope of any segment of a trail shall not be steeper than 1:8 (12%)....
- Figure 810.10 (Exception) Track Crossings – Drawing from the U.S. Access Board