(2) Public entities shall ensure that inmates or detainees with disabilities are housed in the most integrated setting appropriate to the needs of the individuals....
Search Results "Individual Building Test"
Commonly Searched Documents
-
§ 35.152(b)(2)
-
§8.4(b)(1)(iii)
(iii) Provide a qualified individual with handicaps with any housing, aid, benefit, or service that is not as effective in affording the individual an equal opportunity to obtain the same...
-
Can an operator refuse to carry a person with a disability, especially a person using an electric scooter that meets the definition of a “wheelchair,” because of higher insurance rates or liability concerns?
Section 37.5(g) of the DOT ADA regulations prohibits an operator from denying service to an individual with a disability because its insurance company conditions coverage or rates on the...
-
§100.202(d)
(d) Nothing in this subpart requires that a dwelling be made available to an individual whose tenancy would constitute a direct threat to the health or safety of other individuals or whose...
-
§ 35.160(a)(2)
(2) For purposes of this section, “companion” means a family member, friend, or associate of an individual seeking access to a service, program, or activity of a public entity, who, along...
-
Development of the 2004 ADA/ABA Guidelines
In 1994, the Access Board began the process of updating the 1991 ADAAG by establishing an advisory committee composed of members of the design and construction industry, the building code...
- Wikk AccessAbility ™ “Long Ranger” 868 Mhz Transmitters and Receivers
- EZ Dock EZ Launch® System for Kayaks and Canoes
- Symmons Naru Tub/Shower Valve S-4100
-
210 Stairways
The International Building Code and other model building codes provide various exceptions for stairs in assembly areas to permit design features used to accommodate sight lines....
-
Purpose of the Workshop
people with visual impairment So we look to put together some concepts for creating a more high-definition environment for people who are visually impaired so that they can experience buildings...
-
Where Platform Lifts are Permitted [§206.7]
While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building....
-
Section 4.1.5, Additions (Section-By-Section Analysis and Response to Comments)
- Section 4.1.5, Additions (Section-By-Section Analysis and Response to Comments) Each addition to an existing building or facility is regarded as an alteration subject to Sec..36.402...
-
1.3. Public Comments on Initial Regulatory Assessment and Department Responses
The Department received comments from movie industry representatives, individuals with disabilities, advocacy groups representing individuals with disabilities, State and Federal entities...
- HEWI Stainless Steel Pull Handles
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-211.2 Minimum number
The 2013 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
Enforcement Mechanisms
Specifically, the Department requested comment on the effectiveness of: annual surveys to assess the number of projects developed with accessible buildings; recordkeeping requirements; and...
-
2.1 Path of Travel Elements
When alterations or additions are made to existing buildings or facilities, an accessible path of travel to the specific area of alteration or addition shall be provided."...
-
CHAPTER 11A HOUSING ACCESSIBILITY
ETA Editor's Note Sections from California Building Code Chapter 11A not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
11B-211.2 Minimum number
The 2016 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
CHAPTER 11A HOUSING ACCESSIBILITY
ETA Editor's Note Sections from California Building Code Chapter 11A that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....