Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
Search Results "Hinge Side Clearance"
-
11B-404.2.10 Door and gate surfaces
-
POLLING PLACE ACCESSIBILITY IS REQUIRED BY THE AMERICANS WITH DISABILITIES ACT
means that 73% of the polling places used in 2008 had architectural barriers that made it difficult or even impossible for people with disabilities to enter their polling place and vote side...
-
1. Width and Depth of Wheelchair Spaces
NPRM further proposed two alternative depth requirements: 48 inches for wheelchair spaces that are entered from the front or rear, and 60 inches for wheelchair spaces entered from the side...
-
R306.3.2 Pedestrian Activated Signals
a flashing yellow signal, then a steady yellow signal, then two steady red signals during the pedestrian walk interval, and then alternating flashing red signals during the pedestrian clearance...
-
Areas of Rescue Assistance [4.1.3(9), 4.3.11]
The minimum 48 inch width, measured between the leading edge of handrails, provides clearance for assisted evacuation....
-
Minimum Green Times
3.3 6.1 8.5 9.7 Segway 4 4.5 7.8 10.7 13.9 AASHTO calculation 5.2 9.8 11.4 12.8 Pedestrian clearance...
-
1. Access Barrier Removal in Existing Pedestrian Facilities
non-compliant cross-slopes in sidewalks or sections of sidewalks; (7) removal of protruding and overhanging objects and/or obstructions; (8) widening of pedestrian rights of way; (9) providing clearance...
-
2. Follow the Accessibility Standards for Play Areas
Where accessible routes serve ground level play components: • The vertical clearance shall be 80 inches high minimum. • The running slope not steeper than 1:16 or 6.25%....
-
Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)
Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9)...
-
Toilet Compartment Access
If the door and access were from the opposite side, although not as accessible I believe it is also §404 compliant because a self-closing door is not the same as a door with a closer? ...
-
(B) Staircase replacements are alterations that affect or could affect the usability of a public transportation facility or part thereof.
NYCT argues that the “usability” determination in SEPTA II hinges on the fact that the Third Circuit considered the staircase to be “unusable” when it was replaced (or, in NYCT’s words,...
-
Safe Harbor
This could have an extremely significant impact at accessible water closets, because the side clearance requirement from an adjacent lavatory was increased by approximately 7 inches from...
- GameTime Music Time Playground Equipment
- BEA Inc. PBR45 Series Door Access 4.5" Round Push Plate (Push to Open)
- SlabGasket™ Expansion Joint Replacement Solution
- Willoughby Industries ASHS-1013-06-15-HCFA Ligature-Resistant Front Access 15" wide Lavatory
- Sizewise Bari Rehab Platform
- BEA Inc. PBS45 Series Door Access 4.5" Square Push Plate (Push to Open)
- AJW Architectural Products UG30-A Series UG30-A12 12" Concealed Set Screw Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG20-A Series UG20-A12 12" Concealed Set Screw Flange, 1.25" Diameter Grab Bar - Configuration A
- Activar Hiawatha HG111 & HG112 Straight Tubular Pulls and HG113 & HG114 Push Bars
- Door King Inc. 1150 Overhead Gate and Door opener
- Lutron Sivoia QED Kirbé Vertical Motorized Drapery System