That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
Search Results "Ground Surface"
-
Story
-
Background
the contaminant or force is removed, the surface returns to its original condition.”...
-
Literature Cited
Standard specification for impact attenuation of surface systems under and around playground equipment, ASTM F1292....
-
Objectives
The original development work, though targeted toward playground improvements, was eventually seen as a potential improvement for trail surfacing....
-
(c) Thresholds at patio, deck or balcony doors
The final Guidelines provide that exterior deck, patio, or balcony surfaces should be no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
- AJW Architectural Products US18 Collapsable Security Hook, Chase Mounting
- Belson Outdoors Chemical Toilets Portable Sani-Pottie
-
11B-1009.5.4 Transfer steps
The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level. Advisory 11B-1009.5.4 Transfer steps....
-
11B-1009.5.4 Transfer steps
The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level. Advisory 11B-1009.5.4 Transfer steps....
-
Transfer Height
Transfer Height Ride seats designed for transfer must be between 14 and 24 inches above the load and unload area surface....
-
R304.5.2 Grade Breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
Based on the restructure of the transfer surface provisions, described above in Section IV.B.1.b....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
GUARD OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
CURB RAMP
A sloping prepared surface, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
A. Yes. Under Requirement 4, there must be an accessible route into and through the dwelling unit. This would preclude a split level foyer, unless a properly sloped ramp can be...