The 2013 CBC Section 1011.4 requires such a door to be identified by a tactile exit sign with the following words “EXIT STAIR DOWN” or EXIT STAIR UP”....
Search Results "Door Control"
Commonly Searched Documents
-
11B-206.4.1 Entrances and exterior ground floor exits
-
11B-206.4.1 Entrances and exterior ground floor exits
The 2016 CBC Section 1013.4 requires such a door to be identified by a tactile exit sign with the following words “EXIT STAIR DOWN” or EXIT STAIR UP”....
-
11B-206.4.1 Entrances and exterior ground floor exits
The 2019 CBC Section 1013.4 requires such a door to be identified by a tactile exit sign with the following words “EXIT STAIR DOWN” or EXIT STAIR UP”....
-
302.7 With Limited Manipulation
Where a manual mode of operation is provided, ICT shall provide at least one mode of operation that does not require fine motor control or operation of more than one control at the same...
- Schindler's Elevator PORT (Personal Occupant Requirement Terminal)
-
DEPARTMENT OF TRANSPORTATION DISABILITY LAW GUIDANCE: Origin-to-Destination Service
It is reasonable to think that service for some individuals or locations might be better if it is door-to-door, while curb-to-curb might be better in other instances....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
- GE Artistry™ Series 30" Free-Standing Electric Range ABS45DFWS
-
§ 1194.23(k)(2)
(2) Controls and keys shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. ...
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
Exterior Features
Glass garage and barn doors for extra light without extra energy use. Preheated hot water from solar panels for water heater, spa, radiant heating....
-
1007.8.1.1 Visible communication method
Sections 11B-205 and 11B-309 _|Operable Parts|_ in the area of refuge shall activate both a light in the area of refuge indicating that rescue has been requested and a light at the central control...
-
v. Infusion pumps
Infusion pumps Infusion pumps infuse fluids such as chemotherapy drugs, pain medications, or nutrients into the circulatory system in a controlled manner....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall....
-
404.2.11 Vision Lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
§ 37.3 Origin-to-destination service
A provider may provide ADA complementary paratransit in a curb-to-curb or door-to-door mode....
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
Permanently Installed Systems
There are several types of controlled descent devices that can be permanently installed within stairways....
-
§ 1194.25(j)(1)
(1) The position of any operable control shall be determined with respect to a vertical plane, which is 48 inches in length, centered on the operable control, and at the maximum protrusion...
-
Q28. What can my staff do when a service animal is being disruptive?
If a service animal is out of control and the handler does not take effective action to control it, staff may request that the animal be removed from the premises....
-
11B-607.4.1.1 Back wall
Each grab bar shall be installed 15 inches (381 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
Requirements for Platform Lifts
Platform Lift Clear Floor Space and Doors/ Gates...
-
11B-803.1 General
Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms privacy equivalent to that afforded other users of the facility....