Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
Search Results "Door Clear Width"
Commonly Searched Documents
-
11B-1009.5.6 Size
-
Showers
Several commenters requested that the final Guidelines provide dimensions on the appropriate width and height of showers and shower doors....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
4.34.6 KITCHENS
Accessible or adaptable kitchens and their components shall be on an accessible route and shall comply with the requirements of 4.34.6.
- Panda US.51 All Aluminum ULTRA Folding Door System
-
Passing Spaces on Trails
A 60-inch (1,525-millimeter) clear tread width is required for two wheelchairs to pass safely and comfortably on a trail....
-
Co-sharing of Accessible Parking access Aisles by adjacent elevator door allowed?
Given: multistory parking structure circa 1980 with limited head height for vans Issue: Can an elevator door open to and co-share/use an access aisle for an accessible parking space?...
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
1133B.7.1
If a walk or sidewalk has less than 60 inch (1525 mm) clear width, then passing spaces at least 60 inches by 60 inches (1525 mm by 1525 mm) shall be located at reasonable intervals not to...
-
1133A.2.1, Item 3
All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A)....
-
1133A.2.1, Item 3
All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A)....
- Contact Mat (BE9026)
-
Requirements for Platform Lifts
Platform Lift Clear Floor Space and Doors/ Gates...
-
Protruding Objects and Trails
Protruding objects are defined as constructed features such as signs that extend into the clear width area of a trail, resting interval, or passing space between 27 inches (685 millimeters...
-
18. Doors to Inaccessible Areas
[See subsections ...]
-
EXHIBIT F ADA Maintenance Checklist
There also must be sufficient maneuvering room in front of the door on either side. a. Is there an unobstructed clear flat area at the exterior side of the accessible door?...
-
11B-705.2 Detectable directional texture
This surface will be placed directly behind the yellow detectable warning texture specified in Section 11B-705.1.2.1, aligning with all doors of the transit vehicles where passengers will...
-
Uniform Federal Accessibility Guidelines (UFAS)
There are four different scoping requirements that tell you the percentage or absolute number of which of the following types of doors must be accessible: doors going into a building, doors...
-
Emergency Egress
, and the arrangement and location of exit doors....
-
§ 38.53(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where...
-