In the ideal case, planning for a 7.5% running slope allows for construction inaccuracies while still maintaining the required 1:12 slope....
Search Results "Space Allowance"
-
1.2.5 Ramps
-
Paragraph (g) (Advisory Guidance)
Where timed responses are required or appropriate, allow the user to adjust them or set the amount of time allotted to complete a given task....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
604.2 Location
ETA Editor’s Note: The 1991 ADA Standards allowed construction tolerances from an 18” absolute dimension. ...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Problem Two (Entrance)
Solution: Short ramps or wedges may be used on both sides of the threshold to allow a voter in a wheelchair to pass over the threshold....
-
An example of providing a program in a different manner is:
An example of providing a program in a different manner is: A public library that cannot be made accessible can drop books in the mail and allow them to be returned by mail to accommodate...
-
903.6 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
610.4 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
H. Drop-off Area Height
Is the height of the covered passenger pickup/drop-off area at least 9'−6" to allow vans with raised roofs to use such area?...
-
903.6 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
4. Q: What must I do when an individual with a service animal comes to my business?
A: The service animal must be permitted to accompany the individual with a disability to all areas of the facility where customers are normally allowed to go....
-
PLATFORM (WHEELCHAIR) LIFT
platform or support that serves two landings of a building or structure and is designed to carry a passenger or passengers and/or luggage or other material a vertical distance as may be allowed...
-
PLATFORM (WHEELCHAIR) LIFT
platform or support that serves two landings of a building or structure and is designed to carry a passenger or passengers and/or luggage or other material a vertical distance as may be allowed...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
610.4 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
903.6 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
[See subsections ...]
-
Residential Facilities: ADA Standard Section 208.3.2
Section 208.3.2 covers scoping requirements in the current ADA Standards for the location of parking spaces in residential facilities.
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground space...
-
406.2.2 Clear height
While the minimum height is required to be 7'-0" by this section, greater vertical clearance is required at van-accessible parking spaces, standard accessible parking spaces, the vehicular...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground space...
-
11B-502.8.2 Lettering
The additional sign shall clearly state in letters with a minimum height of 1 inch (25 mm) the following: "Unauthorized vehicles parked in designated accessible spaces not displaying...