The final rule also includes a reference indicating that unisex toilet and bathing rooms are also known as "single use or family" facilities....
Search Results "Floor Destination Indicator"
-
Unisex Toilet Rooms
-
Issue 7: Repair/replacement (put it back right!)
When the APS is not correctly installed, there is a risk that a person who is blind will cross a street with the wrong WALK indication or in the wrong direction....
-
Regulatory Flexibility Act
We requested comment in the proposed rule on whether any small entities provide emergency transportable housing units to disaster survivors.51 We did not receive any comments indicating...
-
11B-202 Existing buildings and facilities
Non-compliance with Chapter 11-B must be clearly indicated in the barrier removal documents and signage to truly accessible facilities must be added where necessary....
-
810.2.2 Dimensions
The Department of Transportation in Appendix F of 36 CFR Part 1191 has modified 810.2.2 as follows: Access Board’s Note to Reader: The Department of Transportation’s ADA standards indicate...
-
ii. Accessible scales
Patient weight can serve as a health indicator for many conditions, including depression, diabetes, cancer, cardiovascular disease, high blood pressure, and pregnancy....
-
3.3.12 180-Degree Turn around a Barrier
* indicates data plotted in the graph Figure 3-12. 180-degree turning width around barrier: research findings versus the standards....
-
Summary of Results
When asked if respondents would recommend the trail surface materials on which they reported, many (48.7%) indicated they would, however accompanying comments received provided limited supporting...
-
III-3.8000 Direct threat
ILLUSTRATION 2: Denial of health club membership to an individual who is infected with HIV would be a violation, because current medical evidence indicates that the HIV virus cannot be contracted...
-
11B-216.8 Toilet rooms and bathing rooms
Where existing toilet rooms or bathing rooms do not comply with Section 11B-603, directional signs indicating the location of the nearest toilet room or bathing room complying with Section...
-
11B-216.8 Toilet rooms and bathing rooms
Where existing toilet rooms or bathing rooms do not comply with Section 11B-603, directional signs indicating the location of the nearest toilet room or bathing room complying with Section...
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
Elevators
The "Disco" elevator hoist way entrance lacks raised and Braille floor designations on both jambs and the elevator emergency call system does not operate without voice communication....
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
T402.11 Gaps
When ramps or bridgeplates are deployed for boarding and alighting, gaps between the ramp or bridgeplate surface and floor of non-rail vehicles shall not permit passage of a sphere more...
-
2e
Is there a horizontal grab bar along each of the three shower walls at 33"-36" above the floor as shown in Figure 37(b) below?...
-
H16
Is the toilet stall at least 60 inches wide and 56 inches deep (wall mounted toilet) or 59 inches deep (floor mounted toilet)?...
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
Water Closets [4.16]
Clear floor space requirements at a toilet not located in a stall are different from those for a toilet within a stall....
-
4.6.3 Eyepiece
telescope or periscope that is usable from a seated position for viewing each point of interest shall be positioned 43 inches (1090 mm) minimum and 51 inches (1295 mm) maximum above the floor...
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....