Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground....
Search Results "Floor Destination Indicator"
-
602.7 Drinking Fountains for Standing Persons
-
§ 1194.25(j)(3)
(3) Where any operable control is more than 10 inches and not more than 24 inches behind the reference plane, the height shall be 46 inches maximum and 15 inches minimum above the floor....
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of 1/2 inch (13 mm) under rated loading to...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
Mirrors
Provide a mirror in the Spy City Café men's and women's toilet rooms where the bottom edge of the reflecting surface of the mirror is mounted no more than 40" above the finished floor....
-
1b
Do they have a fixed or folding seat between 17"-19" above the floor, onto which a person who uses a wheelchair may transfer to shower?...
-
H27
Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor?...
-
§100.201 Covered multifamily dwellings
Covered multifamily dwellings means buildings consisting of 4 or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings consisting...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat or manual switch....
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat or manual switch....
-
How Should Testing Entities Report Test Scores for Test-Takers Receiving Disability-Related Accommodations?
“Flagging” is the policy of annotating test scores or otherwise reporting scores in a manner that indicates the exam was taken with a testing accommodation. ...
-
Sections 505.10.2 and 505.10.3
The Department is not aware of any data indicating that an outside diameter of 2 inches would pose any adverse impairment to use by individuals with disabilities....
-
104 Conventions
Commenters recommended that a statement be added indicating that the figures in the guidelines are provided for information purposes only, consistent with the ANSI A117.1 standard....
-
11B-233.3 Residential dwelling units provided by entities not subject to HUD Section 504 Regulations
modifications to the definition of PUBLIC HOUSING in Chapter 2 and modifications to Section 11B-233.2, DSA-AC has modified Section 11B-233.3 above as follows (deleted text not shown; added text indicated...
-
Transfer Compartments
The proposed rule indicated that transfer compartments may have "attachable or integral seats," while folding seats were specified for roll-in showers provided in transient lodging guest...
-
Unisex Toilet Rooms
The final rule also includes a reference indicating that unisex toilet and bathing rooms are also known as "single use or family" facilities....
-
Issue 7: Repair/replacement (put it back right!)
When the APS is not correctly installed, there is a risk that a person who is blind will cross a street with the wrong WALK indication or in the wrong direction....