Injection molded plastic signs feature easy-to-read messages, clear graphics and Grade 2 Braille Signs measure 6"W x 9"H x 1/8" Available in Gray and ADA Blue Double-sided tape...
Search Results "Sign Clear Floor Space"
Commonly Searched Documents
- Seton Economy Braille Signs - Women's Restroom with ISA
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes. The following are the models that can be...
-
A. Arena Assembly Seating:
The floor surface of the Companion Seat shall be at the same elevation as the floor surface of the Wheelchair Seat. ...
-
1150A.1 General
Sites where either Test No. 1 or Test No. 3 is used and it is determined that an accessible route to the common (lobby) entrance is not required, at least 20 percent of the ground floor...
-
221.2.1.2 Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands
In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1....
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1....
-
DIRECTIONAL SIGN
DIRECTIONAL SIGN. [DSA-AC, HCD 1 & HCD 2]. A publicly displayed notice which indicates by use of words or symbols a recommended direction or route of travel....
-
R211 Signs (Section-by-Section Analysis)
R211 Signs (Section-by-Section Analysis) Signs that provide directions, warnings, or other information for pedestrians only and signs that identify routes served by transit stops must...
-
A. ACCESSIBLE SEATING
(“Wheelchair Spaces”). ...
-
5.8.2.3 Overall Knee and Toe Clearance
The overall knee and toe space should be increased to a minimum of 28 inches....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
2. Equipment Clearances for Breast Platforms
The proposed rule included a requirement that 17 inches minimum and 25 inches maximum of the 48-inch wheelchair space depth include knee and toe clearance....
-
a. Knee and Toe Clearance
The MDE Advisory Committee recommended increasing the overall knee and toe space to a minimum 28 inches deep....
-
§ 35.151(g)(1)
(1) In stadiums, arenas, and grandstands, wheelchair spaces and companion seats are dispersed to all levels that include seating served by an accessible route;...
-
5.8.3 Breast Platform Recommendations
The height of the breast platform shall be 30 inches high minimum and 42 inches high maximum above the floor when in use by a patient seated in a wheelchair...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
Accessible Parking
A sign with the international symbol of accessibility must be located in front of the parking space and mounted high enough so it is not hidden by a vehicle parked in the space....
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum....
-
11B-812.6.4 Drive-up
Vehicle spaces serving drive-up EVCS shall be 204 inches (5182 mm) wide minimum and shall not be required to have an adjacent access aisle....
-
11B-812.6.4 Drive-up
Vehicle spaces serving drive-up EVCS shall be 204 inches (5182 mm) wide minimum and shall not be required to have an adjacent access aisle....
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
., at least 32 inches nominal clear width, with no requirements for maneuvering clearances and hardware. (See 56 FR 9487-9488, March 6, 1991, or 24 CFR Ch. I, Subch. A, App. III.)...