height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the raised...
Search Results "Line Spacing (Raised)"
-
11B-1009.2.4 Seat
-
11B-1009.2.4 Seat
height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the raised...
- Access Board: Circular Space
-
11B-246.8 Nature trails
Nature trails and similar educational and informational areas shall be accessible to individuals with vision impairments by the provision of rope guidelines, raised Arabic numerals and symbols...
-
11B-246.8 Nature trails
Nature trails and similar educational and informational areas shall be accessible to individuals with vision impairments by the provision of rope guidelines, raised Arabic numerals and symbols...
-
Knee Clearance: Clearance as Measured from Anterior-Most Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the forward-most point touching the wall....
-
Knee Clearance: Clearance as Measured from Dorsal Foot Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the dorsal foot point touching an obstruction....
-
Call Controls: ADA Standard Section 407.2.1
Section 407.2.1 covers the current ADA Standards for elevator call controls.
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
707.6.3.2 Tactile Symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
707.6.3.2 Tactile Symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
11B.707.7.1.1 Vertically mounted display screen
Where display screens are mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52...
-
11B.707.7.1.1 Vertically mounted display screen
Where display screens are mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52...
-
11B-244.1 General
Religious practice may restrict general access to specific areas, for example a raised altar area; however access for persons with disabilities to these areas may be required....
-
11B-244.1 General
Religious practice may restrict general access to specific areas, for example a raised altar area; however access for persons with disabilities to these areas may be required....
-
National Endowment for the Arts ADA Tip Sheet
National Endowment for the Arts Office of Accessibility 2010 Revised Regulations of the Americans with Disabilities Act Titles II and III
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
-
1015.2 Where required
On the audience side of stages and raised platforms, including stairs leading up to the stage and raised platforms....
-
§382.57(c)(6)(iv)(B) Tactile symbols
Function key surfaces must have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
§27.71(k)(6)(iv)(B) Tactile symbols.
Function key surfaces must have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
§ 27.71(k)(6)(iv)(B) Tactile symbols
Function key surfaces must have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
§ 382.57(c)(6)(iv)(B) Tactile symbols
Function key surfaces must have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
707.6.3.2 Tactile Symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...