The highest operable part of a two-way communication system shall be a maximum of 48 in (1220 mm) from the floor of the car....
Search Results "Maximum Extent Practicable"
-
4.10.14* EMERGENCY COMMUNICATIONS
-
Unified Facilities Guide Specifications
of surface irregularity is to be determined by placing the straightedge on the pavement surface and allowing it to rest on the two highest spots covered by its length and measuring the maximum...
-
[F] 907.4.2.2 Height
The maximum effort to activate controls shall be no greater than 5 pounds-force.◼...
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
11B-705.1.2.3 Islands or cut-through medians
warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches (51 mm) maximum...
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 11B-303.3 Beveled....
-
11B-812.7.2 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center....
-
11B-809.10.5.1 Clear floor space
The area under a lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and...
-
[F] 907.4.2.2 Height
The maximum effort to activate controls shall be no greater than 5 pounds-force. ◼...
- Microsoft: Make your PowerPoint presentations accessible
- National Organization of Nurses with Disabilities (NOND)
- Increasing Opportunities for Access on the Appalachian Trail: A Design Guide
- Easterseals Blake Foundation
- Independent Living Resource Center, INC. - Santa Barbara, Atascadero, Santa Maria, Ventura, Concord, Antioch, Fairfield, CA
-
Subpart E—Enforcement (Section-By-Section Analysis and Response to Comments)
to make new construction and alterations accessible "shall include'' an order to alter these facilities to make them readily accessible to and usable by persons with disabilities to the extent...
- Nuance Power PDF with RMS Security
-
Sales and Service Counters
In addition to having a maximum height of 36 inches, all accessible sales and service counters must have a clear floor space in front of the accessible surface that permits a customer using...
-
Trailhead Information Signs [F216.13 and 1017.10]
signs must include the following information: Length of the trail or trail segment Type of trail surface Typical and minimum trail tread width Typical and maximum...
-
Transfer Sides (M301.2.3 and M302.2.3)
The Access Board is considering whether the final standards should permit equipment parts to extend horizontally 3 inches maximum beyond the edge of the transfer sides provided they do not...
-
1134A.5 Bathtubs
The area under a lavatory, located at the control end of the tub, may be included in the clear floor space provided the lavatory is 19 inches (483 mm) maximum deep, and the knee and toe...
-
5.8.2 Knee and Toe Clearance Recommendations under Breast Platform Recommendations
The depth of the wheelchair space shall include knee and toe clearance of 17 inches minimum and 25 inches maximum....
-
Sections 35.108(d)(1)(i) and 36.105(d)(1)(i)—Broad Construction, Not a Demanding Standard
Department, in its NPRM, proposed §§ 35.108(d)(1)(i) and 36.105(d)(1)(i), which state: ‘‘The term ‘substantially limits’ shall be construed broadly in favor of expansive coverage, to the maximum...
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
The standards will allow independent entry to, use of, and exit from the equipment by individuals with disabilities to the maximum extent possible....
-
Integration of inmates and detainees with disabilities. (Section-by-Section Analysis)
The vast majority of commenters asserted that, given the practice of many public entities to segregate and cluster inmates with disabilities, the exception will be used to justify the status...