ETA Editor's Note Top-mounted sinks installed in counters having the top surface 34 inches above the floor will exceed the maximum rim height allowed, regardless of how thin the flange...
Search Results "AHJ: Authority Having Jurisdiction"
-
11B-606.3 Height
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-502.7.1 Arrangement
This section requires that persons with disabilities not be required to travel behind parking spaces other than the one in which they have parked. ◼ ETA Editor's Note While 2010...
-
11B-502.7.1 Arrangement
This section requires that persons with disabilities not be required to travel behind parking spaces other than the one in which they have parked. ◼ ETA Editor's Note While 2010...
-
11B-606.3 Height
ETA Editor's Note Top-mounted sinks installed in counters having the top surface 34 inches above the floor will exceed the maximum rim height allowed, regardless of how thin the flange...
-
Water Play Components: ADA Standard Section 1008.2.3
Some may have batteries, motors, and electrical systems that when submerged in water may cause damage to the personal mobility device or wheelchair or may contaminate the water....
-
James E. Woods, Ph.D., P.E. Natural Lighting for Persons with Low Vision
The other issue is: what happens if you don’t have daylight and you need the function? You still have to have lighting provision for the functions....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION...
-
11B-224.7.1 Multi-bedroom housing units with mobility features
Multi-bedroom housing units containing accessible sleeping rooms with mobility features shall have an accessible route throughout the unit in compliance with Section 11B-809.2....
-
11B-703.2 Raised characters
Signs that are designed to be read by touch should not have sharp or abrasive edges....
-
F106.2 Terms Defined in Referenced Standards
the Secretary of Housing and Urban Development, or the United States Postal Service to implement the Architectural Barriers Act but specifically defined in a referenced standard, shall have...
-
Individual with a Disability
has a physical or mental impairment that, on a permanent or temporary basis, substantially limits one or more major life activities, has a record of such an impairment, or is regarded as having...
-
Turning Space
Turning Space Piers and platforms must have at least one turning area, either a 60-inch turning space or T-shaped space, to allow a person using a mobility device or wheelchair to make...
-
Wading Pools
The sloped entries for wading pools are not required to have handrails....
-
Protruding objects and vitrines
Add aprons, extend bases, or add barriers below objects and vitrines that project more than 4" from walls and have their leading edges greater than 27" and less than 80" above the finished...
-
Suspicious Minds Ramp
The ramp leading to the exhibits has a rise greater than 6", but does not have the required handrails on both sides. See Standards § 4.8.5. q....
-
C204.1 General
Where components of telecommunications equipment and customer premises equipment are hardware, and transmit information or have a user interface, those components shall conform to applicable...
-
2. Door Hardware
the bathroom door hardware (levers, pulls, etc.) easily operable with one hand, without tight grasping, pinching or twisting of the wrist, since many persons with disabilities may not have...
-
§ 35.150(b)(4)(i)
where an existing play area provides elevated play components, an additional number of ground level play components may be substituted for the number of elevated play components that would have...
-
9. Faucet Control
Does the lavatory in each accessible guestroom bathroom have a faucet that is easily operable (i.e.: levers, wrist blades, single arm, etc.) and usable with one hand, without tight grasping...
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...