Fire Safety Evacuation Planning
-
1132A.3 Width and height of interior doors and secondary exterior doors
The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
(c) Thresholds at patio, deck or balcony doors
The final Guidelines provide that exterior deck, patio, or balcony surfaces should be no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed...
-
12182(b)(2)(B)(ii) Equivalent service
usable by individuals with disabilities, it shall be considered discrimination for such entity to fail to operate such system so that, when viewed in its entirety, such system ensures a level...
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this chapter....
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
M301.4 Lift Compatibility
Equipment components are permitted to be located within 8 inches (205 mm) maximum of the centerline of the clearance width....
-
Section 2. Undisturbed site
"Undisturbed site" means the site before any construction, levelling, grading, or development associated with the current project....
-
§ 35.151(g)(1)
(1) Wheelchair and companion seating locations are dispersed among all levels of the facility that are served by an accessible route;...
-
1009.2, Item 10
Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge....
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
Seat Height
The proposed rule specified that the bench seat be 17 to 19 inches above the floor or ground (903.4)....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
11B.707.7.1.3 Horizontally mounted display screen
viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor or ground...
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
612.2 Bench
EXCEPTION: A readily removable bench shall be permitted to obstruct the turning space required by 612.3 and the clear floor or ground space required by 903.2....
-
11B-704.3 Volume control telephones
If a volume adjustment is provided that allows the user to set the level anywhere from the base volume to the upper requirement of 20 dB, there is no need to specify a lower limit....
-
11B-704.3 Volume control telephones
If a volume adjustment is provided that allows the user to set the level anywhere from the base volume to the upper requirement of 20 dB, there is no need to specify a lower limit....
-
11B-206.2.2 Within a site
While the size of an area of sport activity may vary from sport to sport, each includes only the space needed to play....