Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
Search Results "Ground Level Play Component"
Commonly Searched Documents
-
11B-407.2.2.2 Visible signals
-
4.9.4(2)
At the top, the extension shall be parallel with the floor or ground surface....
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
II-3.2000 Denial of participation.
The ADA, like other civil rights statutes, prohibits the denial of services or benefits on specified discriminatory grounds....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Control buttons shall be located no higher than 48 inches (1219 mm) above the ground surface adjacent to the pole....
-
11B-1009.2.8 Submerged depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
§ 1194.23(i)
(i) Interference to hearing technologies (including hearing aids, cochlear implants, and assistive listening devices) shall be reduced to the lowest possible level that allows a user of...
-
d-vi
Does the ramp have a level landing that is at least 60 inches long at the top and bottom of each ramp section or where the ramp changes direction?...
-
7(2)(a)(iii)
(iii) If the shower stall is the only bathing facility provided in the covered dwelling unit, or on the accessible level of a covered multistory unit, the shower stall measures at least...
-
12162(a)(4)(B)(i)
(i) if such train includes a bi-level lounge car purchased after July 26, 1990, table service in such lounge car shall be provided to individuals who use wheelchairs and to other passengers...
-
§35.130(b)(1)(iii)
individual with a disability with an aid, benefit, or service that is not as effective in affording equal opportunity to obtain the same result, to gain the same benefit, or to reach the same level...
-
A4.3.1(2) Sites
Level, indirect routes or those with running slopes lower than 1:20 can sometimes provide more convenience than direct routes with maximum allowable slopes or with ramps....
-
A4.3.1(2) Sites
Level, indirect routes or those with running slopes lower than 1:20 can sometimes provide more convenience than direct routes with maximum allowable slopes or with ramps....
-
§1193.43(h) Non-interference with hearing technologies
Reduce interference to hearing technologies (including hearing aids, cochlear implants, and assistive listening devices) to the lowest possible level that allows a user to utilize the product...
-
§ 35.130(b)(1)(iii)
individual with a disability with an aid, benefit, or service that is not as effective in affording equal opportunity to obtain the same result, to gain the same benefit, or to reach the same level...
-
§ 37.3 Light rail
Service may be provided by step-entry vehicles or by level boarding....
-
C. Air Travelers with a Disability Changing Planes
[Sec. 382.39(a)(1)] NOTE: Carriers must not leave a passenger with a disability unattended in a ground wheelchair or other device in which the passenger is not independently mobile for more...
-
§35.131(b) (Section-by-Section Analysis)
A health care facility, such as a hospital or clinic, may not refuse treatment to an individual in need of the services it provides on the grounds that the individual is illegally using...
-
Step 1: Determine the Applicability of FSTAG
Design Tip Evaluate your trail design for Forest Service Trail Accessibility Guidelines (FSTAG) compliance using on-the-ground layout....
-
206.7.5 Existing Site Constraints
For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public...
-
702.1 General
installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1), except that the maximum allowable sound level...
-
Q10: Two or More 'Maintenance' Treatments
Q10: When does a combination of two or more ‘maintenance’ treatments rise to the level of being an alteration?...
-
11B-206.7.5 Existing site constraints
For example, a new building constructed between and connected to two existing buildings may have insufficient space to coordinate floor levels and also to provide ramped entry from the public...