Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
Search Results "ALI: Automatic Location Identification"
Commonly Searched Documents
-
11B-606.6 Adjacent side wall or partition
-
Sec.36.404(a)(1)
(1) For the purposes of this section, "professional office of a health care provider'' means a location where a person or entity regulated by a State to provide professional services related...
-
M302.2.1 Adjustability
At least 4 additional transfer positions located between the low and high transfer positions and separated by 1 inch (25 mm) minimum....
-
Section 36.406(f) Assembly Areas
The NPRM proposed at Sec. 36.406(f)(1) to require wheelchair spaces and companion seating locations to be dispersed to all levels of the facility that are served by an accessible route....
-
11B-806.3.2 Notification devices
Telephones shall be served by an electrical outlet complying with Section 11B-309 located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY....
-
404.2.11 Vision Lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located...
-
1009.2.3 Clear Deck Space
The space shall be 36 inches (915 mm) wide minimum and shall extend forward 48 inches (1220 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
What Are the Requirements for Accessible Routes?
This section describes the various features of accessible routes within a play area, including location, clear width, slope, and accessible surfaces. ...
-
5. Site Constraints, Technical Infeasibility, and Unusually Expensive Remediation
Locations at which site constraints make compliance with applicable design standards impracticable may be made compliant with the standards to the maximum extent feasible....
-
1009.3.2 Submerged Depth
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
R309.1 General
Accessible parking spaces should be located where the street has the least crown and grade and close to key destinations....
-
(d) Outside surface at entry door
The Guidelines further provide that the finished surface of this area, located immediately outside the entry door, may be sloped for drainage, but the sloping may be no more than 1/8 inch...
-
Gift Shops
Offer assistance with locating items and reading price tags. Identify individual bills when handing currency to a guest....
-
11B-505.5 Clearance
Handrails may be located in a recess if the recess is 3 inches (76 mm) maximum deep and 18 inches (457 mm) minimum clear above the top of the handrail. [2010 ADAS] 505.5 Clearance. ...
-
§ 36.404(a)(1)
(1) For the purposes of this section, "professional office of a health care provider" means a location where a person or entity regulated by a State to provide professional services related...
-
4.3.11.1(7)
Such pressurization system shall be activated by smoke detectors on each floor located in a manner approved by the appropriate local authority....
-
Dispensers [4.16.6]
Dispensers [4.16.6] Toilet paper dispensers should be located below the side grab bar so that they do not obstruct use of this bar....
-
5.1 GENERAL
there are mezzanine levels, loggias, or raised platforms, accessibility to all such spaces is not required providing that the same services and decorative character are provided in spaces located...
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the recreation access route....
-
1015.1 General
The technical requirements address the clear ground space (1015.2) and viewing space (1015.3) at distinct viewing locations; the turning space within viewing areas (1015.4); and the surface...
-
4.16.2 Clear Floor Space
As a result, toilet room configuration and location of the water closet were the critical design considerations in assisted transfers....
-
4.5.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...