Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
Search Results "Stairway"
Commonly Searched Documents
-
505.1 General
-
[2010 ADAS] 105.2 Referenced Standards
, 11B-411.1, 11B-810.9, 1607.8.1, 1607.9.1, 3001.2, 3001.4, 3002.5, 3003.2, 3007.1, 3008.1.3, 3008.7.1 A18.1-2008 Safety Standard for Platform Lifts and Stairway...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or stairway. 3. ...
-
505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 General 11B-502 Parking Spaces 11B-503 Passenger Drop-Off and Loading Zones 11B-504 Stairways...
-
Vertical Clearance [§307.4]
Fixed barriers, such as guardrails, are required where the vertical clearance is less than 80” such as at open stairways and along sloped or curved walls....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or stairway. 3....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings serving an adjoining ramp run or stairway....
-
11B-505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
11B-505.1 General
Handrails are required on ramp runs with a rise greater than 6 inches (150 mm) (see 405.8) and on certain stairways (see 504)....
-
A. Signs
__ No __ N/A __ Comments: ___________________________________________ Mechanical and electrical rooms Yes __ No __ N/A __ Comments: ___________________________________________ Stairways...
-
Pictograms and Symbols of Accessibility [ADA Standards §216.2 , §703.6, §703.7]
Pictograms and Symbols of Accessibility [ADA Standards §216.2 , §703.6, §703.7] Where pictograms are provided to identify a permanent room or space, such as a stairway, they must...
-
5) Areas of rescue assistance or places of refuge
Specific requirements are provided for such features as location, size, stairway width, and two-way communications....
-
ICC/IBC: ADA Standard Section 105.2.4
Section 105.2.4 of the ADA Standards cover references to the International Code Council (ICC) and the International Building Code (IBC).
-
Fire Department Issues
Some fire departments mistakenly believe that they can jam up the stairways. This is not the case....
-
Question: Alteration vs. Maintenance for Stairs in Pre-ADA Building
Or would replacing the handrails be considered an alteration that affects usability—thereby triggering a requirement to upgrade the entire stairway to current accessibility standards?...
-
Table of Contents
Exceptions 204 Protruding Objects 205 Operable Parts 206 Accessible Routes 207 Accessible Means of Egress 208 Parking Spaces 209 Passenger Loading Zone and Bus Stops 210 Stairways...
-
Interior Routes
. 11B-307 Running and cross slopes at walking surfaces and ramps. 11B-403.3 11B-405 Handrails on ramps and stairways...
-
Interior Routes
. 11B-307 Running and cross slopes at walking surfaces and ramps. 11B-403.3 11B-405 Handrails on ramps and stairways...
- Garaventa Artira Inclined Platform Wheelchair Lift
-
General
safety features that can be used for emergency evacuation of individuals with disabilities in facilities with four or more stories above or below the exit discharge level, and allows exit stairways...
-
Master the Skill of Giving Quick Information on How Best to Assist You
You have to carry me out, wheelchair user evacuation chairs are hung at the top of “stairway two, north end” and “stairway three, south end.”...
-
Can a more recent edition of the ASME A17.1 Safety Code for Elevators and Escalators (or the ASME A18.1 Safety Standard for Platform Lifts and Stairway Chairlifts) be used instead of the editions referenced in the Standards?
The specific editions of the ASME A17.1 and ASME A18.1 codes referenced by the ADA Standards are to be followed (although the Access Board intends to update references to keep them...
-
1013.4 Raised character and braille exit signs
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...