Search Results "Side Reach"
- Figure 404.2.4.1(e) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(f) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(h) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(j) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(d) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(i) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side with Closer – Drawing from the U.S. Access Board
-
4.1.3(12)(a)
(a) If fixed or built-in storage facilities such as cabinets, shelves, closets, and drawers are provided in accessible spaces, at least one of each type provided shall contain...
-
I1a
For a side approach (clear floor space at least 30 inches long x 48 inches wide), is the coin slot no higher than 54 inches above the floor?...
- Figure 404.2.4.1(g) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
-
1007.3.2 Golf Club Reach Range Area
1007.3.2 Golf Club Reach Range Area....
-
1007.3.2 Golf Club Reach Range Area
Advisory 1007.3.2 Golf Club Reach Range Area. The golf club reach range applies to all holes required to be accessible....
-
D4
On the latch, pull side of the door, is there at least 18 inches clearance provided if the door is not automatic or power-operated?...
-
1008.4.2 Clear Floor or Ground Space
The following table provides guidance on reach ranges for children seated in wheelchairs. These dimensions apply to either forward or side reaches....
-
1008.4.2 Clear Floor or Ground Space
The following table provides guidance on reach ranges for children seated in wheelchairs. These dimensions apply to either forward or side reaches....
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface....
-
Re: Section 307 Protruding Objects
Yes, it is a protruding object hazard based solely on section 307, but so is the (code compliant) lavatory with its (required) 29" high front edge, and the 8" deep (code compliant)...
-
Section 307 Protruding Objects
This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?
-
11B-406.5.1 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
11B-406.5.1 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
1007.3.2 Golf Club Reach Range Area
Advisory 1007.3.2 Golf Club Reach Range Area. The golf club reach range applies to all holes required to be accessible....
-
11B-1007.3.2 Golf club reach range area
[2010 ADAS] Advisory 1007.3.2 Golf Club Reach Range Area. The golf club reach range applies to all holes required to be accessible....
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
These orientations are now identified as an end transfer surface and side transfer surface....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm)...