In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
Search Results "Shall"
Commonly Searched Documents
-
11B-608.3.3 Alternate roll-in type shower compartments
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-503.4 Floor and ground surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
Re: Lavatories Adjacent to Partitions
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
11B-502.3.4 Location
Access aisles shall not overlap the vehicular way....
-
General: ADA Standard Section 206.1
Section 206.1 of the ADA Standards covers information on scoping requirements for accessible routes in the most current ADA Standards.
-
Detectable Warnings: ADA Standard Section 705
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705....
-
General: ADA Standard Section 219.1
Section 219.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for assistive listening systems.
-
General: ADA Standard Section 705.1
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705....
-
Type: ADA Standard Section 407.3.1
Section 407.3.1 covers the current ADA Standards for elevator door type.
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
-
Extended Ground or Deck Surface: ADA Standard Section 1005.3.2
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
-
11B-308.1.1 Electrical switches
Controls and switches intended to be used by the occupant of a room or area to control lighting and receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing....
-
11B-810.8 Clocks
Where clocks are provided for use by the public, the clock face shall be uncluttered so that its elements are clearly visible....
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
11B-411.2.1.3.4 Position
Display screens and touch screens shall be positioned so glare is reduced on the screen. Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
Toilet Rooms and Bathing Rooms: ADA Standard Section 216.8
Section 216.8 covers scoping requirements in the current ADA Standards for signs at toilet rooms and bathing rooms.
-
Grab Bars: ADA Standard Section 608.3
Section 608.3 covers the current ADA Standards for grab bars in shower compartments.
-
11B-405.9 Edge protection
Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings....
-
Forward Approach: ADA Standard Section 904.4.2
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....