Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
Search Results "Section 504"
-
11B-505.7.2 Non-circular cross sections
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
-
A. Executive Order 13563 and 12866—Regulatory Planning and Review
504 of the Rehabilitation Act....
-
1130A.1 General
For the purpose of this section, “accessible routes” may include hallways, corridors and ramps....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
1134A.8 Lavatories, vanities, mirrors and towel fixtures. Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory. Where mirrors and towel...
-
1134A.6, Item 2
2. Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum or...
-
1135A.1 General
1135A.1 General. If clothes washing machines and clothes dryers are provided in covered multifamily dwelling units, one of each type of appliance shall be provided. Where...
-
1134A.5, Item 2
2. Reinforced walls for grab bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars. Where a...
-
1134A.6, Item 6
6. Shower controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.6, Item 5
5. Thresholds. When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units...
-
1134A.8, Item 5
5. Finished floor. The finished floor beneath the lavatory shall be extended to the wall.
-
1134A.7, Item 2
2. Reinforced walls for grab bars. Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for...
-
1134A.5, Item 2
2. Reinforced walls for grab bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars. Where a bathtub is...
-
1134A.6, Item 6
6. Shower controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.6, Item 2
2. Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum or...
-
1134A.8, Item 5
5. Finished floor. The finished floor beneath the lavatory shall be extended to the wall.
-
1134A.8, Item 7
7. Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The...
-
1134A.6, Item 5
5. Thresholds. When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal...
-
1134A.7, Item 2
2. Reinforced walls for grab bars. Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for...
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory. Where mirrors and towel fixtures are provided, at least one of each shall be...
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall comply with the following: Sinks and work surfaces required by Section 1133A.4 shall be designed to enable repositioning to a minimum height of 28...
-
Non-Circular Cross Section and Clearance (§505.5, §505.7)
Non-Circular Cross Section and Clearance (§505.5, §505.7)...