must be able to approach the exam table and any other elements of the room to which patients have access....
Search Results "Patient Toilet Room"
-
Clear Floor and Turning Space Inside Examination Rooms
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
mm) thick triangle with a vertex pointing upward, superimposed on and geometrically inscribed within the circle and within the 12-inch diameter, shall be provided at entrances to unisex toilet...
-
SECTION 1134A BATHING AND TOILET FACILITIES
[See subsections ...]
-
SECTION 1134A BATHING AND TOILET FACILITIES
[See subsections ...]
-
§ 35.151(b)(4)(i)(A)
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function. ...
-
§ 35.151(b)(4)(i)(A)
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function....
-
223.2.1 Facilities Not Specializing in Treating Conditions That Affect Mobility
In facilities not specializing in treating conditions that affect mobility, at least 10 percent, but no fewer than one, of the patient sleeping rooms shall provide mobility features complying...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
A combined circle and triangle symbol shall be located at entrances to unisex toilet and bathing facilities....
-
11B-202 Existing buildings and facilities
Consequently, the patient toilet serving the non-accessible patient room may not need to be made accessible....
-
Section 35.151(h) Medical care facilities
When accessible rooms are not fully dispersed, a person with a disability is often placed in an accessible room in an area that is not medically appropriate for his or her condition, and...
-
Section 36.406(g) Medical Care Facilities
When accessible rooms are not fully dispersed, a person with a disability is often placed in an accessible room in an area that is not medically appropriate for his or her condition, and...
-
223.2.1 Facilities Not Specializing in Treating Conditions That Affect Mobility
In facilities not specializing in treating conditions that affect mobility, at least 10 percent, but no fewer than one, of the patient sleeping rooms shall provide mobility features complying...
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
Water Closet Location.
Staff felt that 24" would provide sufficient space for them to fit on both sides of the toilet and still permit a patient to reach the wall-mounted toilet paper holder without falling off...
-
F223.1.1 Alterations
Where sleeping rooms are altered or added, the requirements of F223 shall apply only to the sleeping rooms being altered or added until the number of sleeping rooms complies with the minimum...
-
223.1.1 Alterations
Where sleeping rooms are altered or added, the requirements of 223 shall apply only to the sleeping rooms being altered or added until the number of sleeping rooms complies with the minimum...
-
223.1.1 Alterations
Where sleeping rooms are altered or added, the requirements of 223 shall apply only to the sleeping rooms being altered or added until the number of sleeping rooms complies with the minimum...
-
6.3(2)
(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....
-
Question 20
Is the required floor and wall space inside public restrooms and fitting rooms blocked by obstacles such as trash cans, chairs, or shelving?...
-
Dressing, Fitting, and Locker Rooms: ADA Standard Section 222
Section 222 covers scoping requirements in the current ADA Standards for dressing, fitting, and locker rooms.
-
Dressing, Fitting, and Locker Rooms: ADA Standard Section 803
[See subsections ...]
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
6.3(1)
(1) Each bedroom shall have a turning space that complies with 4.2.3, and preferably that is located near the entrance.
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...