1.1.6 Flatness of walk cross slope....
Search Results "Midblock Pedestrian Street Crossing"
Commonly Searched Documents
-
1.1.6 Flatness of walk cross slope
-
4.1.3(8)(b)(ii)
(ii) If access is provided for pedestrians from a pedestrian tunnel or elevated walkway, one entrance to the building from each tunnel or walkway must be accessible....
-
3 [§ 4.3.7]
3 [§ 4.3.7] The cross slope of the curb ramp is perpendicular to the running slope. Unlike the running slope, which runs along the ramp, the cross slope is measured across the ramp....
-
F248.2 Minimum Number
EXCEPTION: The number of beach access routes shall not be required to exceed the number of pedestrian access points provided by the entity to a beach....
-
505.7.2 Non-Circular Cross Sections
505.7.2 Non-Circular Cross Sections....
-
Location: ADA Standard Section 406.5
Section 406.5 covers the current ADA Standards for the location of curb ramps.
-
Accessible Route - Exterior
Error/Omission: The pedestrian routes on a site from public transportation stops, accessible parking spaces, passenger loading zones, and public streets and sidewalks to the accessible...
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-403.3 Slope
The cross slope of walking surfaces shall not be steeper than 1:48....
-
11B-403.3 Slope
The cross slope of walking surfaces shall not be steeper than 1:48....
- Landscape Forms Inc. Scarborough Bench Collection
-
1.2.7
1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope....
-
Non-Circular Cross Section and Clearance (§505.5, §505.7)
Non-Circular Cross Section and Clearance Recommendation: Projecting objects above handrails can impact their usability....
-
1.1.2 Walks
Measure walks and other non - ramp pedestrian surfaces for overall running slope and cross slope as well as local running slope and cross slope variations (flatness) in accordance with 1.1.3...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section dimension of...
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance (§505.5, §505.7)...
-
F248.3 Location
Beach access routes shall coincide with or be located in the same area as pedestrian access points to the beach....
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
R404.6 Approach
One full unobstructed side of a clear space shall adjoin a pedestrian access route or adjoin another clear space....
-
Managed Use
For example, a trail may be managed for both equestrian and hiker/pedestrian use in the summer and for cross-country skiing in the winter....
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...