Common Problems with Signs Ø Some signs – such as permanent room signs – are required to have Braille, high contrast, and raised lettering and must be located on the wall to...
Search Results "Horizontal Exit"
Commonly Searched Documents
-
Common Problems with Signs
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
703.5.4 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I".
-
703.5.4 Character Proportions
Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I".
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
703.5.8 Character Spacing
703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
703.5.4 Character Proportions
703.5.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the...
-
11B-703.5.4 Character proportions
11B-703.5.4 Character proportions. Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of...
-
11B-703.5.8 Character spacing
11B-703.5.8 Character spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
R302.7.3 Horizontal Openings
R302.7.3 Horizontal Openings. Horizontal openings in gratings and joints shall not permit passage of a sphere more than 13 mm (0.5 in) in diameter....
-
11B-216.2 Designations
Tactile exit signs complying with Chapter 10 contribute to a safe environment for people with visual impairments. ◼...
-
In Your Guest Room:
the shortest route. 1.1.2 Count the number of doors and turns from your room door to exits. 1.1.3 Make sure the exits are unlocked....
-
Standards Specific to Assembly Areas
Dispersion of Wheelchair Spaces: Box Seats: Wheelchair spaces must be provided and located in not fewer than 20% of all boxes.Wheelchair spaces must be dispersed vertically, horizontally...
-
Sec.36.308(a) Existing facilities
(a) Existing facilities.
-
11B-216.2 Designations
Tactile exit signs complying with Chapter 10 contribute to a safe environment for people with visual impairments. ◼...
- SDC S6000 Spectra Exit Devices
-
F216.1 General
Signs shall be provided in accordance with F216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas, occupant names,...
-
703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. [S.H. Visual character style not addressed...
-
703.1 General
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...